Bio-Medical Materials and Engineering - Volume 24, issue 6
Purchase individual online access for 1 year to this journal.
Price: EUR 245.00
Impact Factor 2024: 1.0
The aim of
Bio-Medical Materials and Engineering is to promote the welfare of humans and to help them keep healthy. This international journal is an interdisciplinary journal that publishes original research papers, review articles and brief notes on materials and engineering for biological and medical systems.
Articles in this peer-reviewed journal cover a wide range of topics, including, but not limited to: Engineering as applied to improving diagnosis, therapy, and prevention of disease and injury, and better substitutes for damaged or disabled human organs; Studies of biomaterial interactions with the human body, bio-compatibility, interfacial and interaction problems; Biomechanical behavior under biological and/or medical conditions; Mechanical and biological properties of membrane biomaterials; Cellular and tissue engineering, physiological, biophysical, biochemical bioengineering aspects; Implant failure fields and degradation of implants. Biomimetics engineering and materials including system analysis as supporter for aged people and as rehabilitation; Bioengineering and materials technology as applied to the decontamination against environmental problems; Biosensors, bioreactors, bioprocess instrumentation and control system; Application to food engineering; Standardization problems on biomaterials and related products; Assessment of reliability and safety of biomedical materials and man-machine systems; and Product liability of biomaterials and related products.
Abstract: Skull defect reconstruction is an important aspect of surgical repair. Historically, a skull defect prosthesis was created by the mirroring technique, surface fitting, or formed templates. These methods are not based on the anatomy of the individual patient's skull, and therefore, the prosthesis cannot precisely correct the defect. This study presented a new hybrid level set model, taking into account both the global optimization region information and the local accuracy edge information, while avoiding re-initialization during the evolution of the level set function. Based on the new method, a skull defect was reconstructed, and the skull prosthesis was produced by…rapid prototyping technology. This resulted in a skull defect prosthesis that well matched the skull defect with excellent individual adaptation.
Show more
Keywords: Skull defect, image segmentation, level set method, rapid prototyping
Abstract: Having the ability to visualize the heart clearly and precisely would be beneficial for pathology research, presurgical planning, and clinical approaches. Multi-dimensional transfer functions were employed to improve the overall performance of images. To provide a satisfactory visualization quality on the shape and boundaries of the heart, a new hybrid transfer function combining structure size with gradient was designed to highlight the area of the heart. Initially, a histogram of gradient and histogram of size was computed and then classification was performed for providing the spatial information. Finally, several hybrid strategies were presented for the design of the transfer function,…including opacity and color. By experimental evaluation, the proposed hybrid transfer function visualized the cardiac outline and internal structure more clearly and easily.
Show more
Keywords: visualization of heart, multi-dimensional transfer function, histogram of structure size, histogram of gradient
Abstract: The rigid registration is a key step of Image Guided Surgery (IGS), and the point-pair method is the main way used for registration. However the configuration of fiducial points has a great influence on the registration accuracy at the target point. Now almost all the optimization method of fiducial points configuration relies on the empirical simulation-based Fitzpatrick's target registration error (TRE). In this paper, a phantom and some markers were designed and some experiments were conducted to measure and compare the affecting factors on the registration. By the markers repeated selections, the fiducial location error (FLE) has a small deviation…of maximum 0.4 mm, and the average of the Fitzpatrick's TRE (F-TRE) has almost 86% proportion to the average of the actual TRE (A-TRE), but the standard deviation (STD) just has 7% proportion. Also, the experiment result showed that six fiducial markers already had the 86% accuracy, and spreading the fiducial markers led to 30% reduction in mean of A-TRE and 40% reduction in STD of A-TRE comparing with the centralized. Overall, to find a strategy of optimization, reducing the TRE has the great meaning to support safer and more accurate minimally IGS procedures.
Show more
Keywords: Image guided surgery, target registration error, registration, fiducial markers, number and distribution
Abstract: Multiple myeloma (MM)-induced bone disease is mortal for most MM patients. Bisphosphonates are first-line treatment for MM-induced bone disease, since it can inhibit osteoclast activity and the resultant bone resorption by suppressing the differentiation of osteoclast precursors into mature osteoclasts, promoting osteoclast apoptosis and disrupting osteoclast function. However, it is still unclear whether bisphosphonates have an anti-tumour effect. In our previous work, a computational model was built to simulate the pathology of MM-induced bone disease. This paper extends this proposed computational model to investigate the efficacy of bisphosphonates treatment and then clear the controversy of this therapy. The extended model…is validated through the good agreement between simulation results and experimental data. The simulation results suggest that bisphosphonates indeed have an anti-tumour effect.
Show more
Keywords: Multiple myeloma, MM-induced bone disease, bisphosphonates, anti-tumour, computational model
Abstract: This work was aimed at studying the method of computer-aided diagnosis of early knee OA (OA: osteoarthritis). Based on the technique of MRI (MRI: Magnetic Resonance Imaging) T2 Mapping, through computer image processing, feature extraction, calculation and analysis via constructing a classifier, an effective computer-aided diagnosis method for knee OA was created to assist doctors in their accurate, timely and convenient detection of potential risk of OA. In order to evaluate this method, a total of 1380 data from the MRI images of 46 samples of knee joints were collected. These data were then modeled through linear regression on an…offline general platform by the use of the ImageJ software, and a map of the physical parameter T2 was reconstructed. After the image processing, the T2 values of ten regions in the WORMS (WORMS: Whole-organ Magnetic Resonance Imaging Score) areas of the articular cartilage were extracted to be used as the eigenvalues in data mining. Then,a RBF (RBF: Radical Basis Function) network classifier was built to classify and identify the collected data. The classifier exhibited a final identification accuracy of 75%, indicating a good result of assisting diagnosis. Since the knee OA classifier constituted by a weights-directly-determined RBF neural network didn't require any iteration, our results demonstrated that the optimal weights, appropriate center and variance could be yielded through simple procedures. Furthermore, the accuracy for both the training samples and the testing samples from the normal group could reach 100%. Finally, the classifier was superior both in time efficiency and classification performance to the frequently used classifiers based on iterative learning. Thus it was suitable to be used as an aid to computer-aided diagnosis of early knee OA.
Show more
Abstract: Silicosis remains one of the most harmful occupational respiratory diseases. It threatens the workers exposed to dust environment. Chest radiograph is the main available image source for silicosis diagnosis according to the diagnostic criteria of pneumoconiosis (DCP). Automatic detection and recognition of silicosis in chest radiograph has great importance on aiding the process of silicosis diagnosis. This paper proposes a multi-scale opacity detection approach to detect all suspected opacities from the chest radiograph. A support vector machine (SVM) based computer-aided silicosis diagnosis is proposed to recognize silicosis opacity from a large amount of candidate regions, and gives processing result for…radiologist reference. Comprehensive experiments conducted on real world chest radiographs demonstrate that the proposed approach can reveal changes of silicosis pathology well, and it can be adopted as an effective tool for automatic silicosis diagnosis.
Show more
Keywords: Silicosis, diagnostic criteria of pneumoconiosis, chest radiograph, support vector machine, silicosis pathology
Abstract: The frequent occurrence of breast cancer and its serious consequences have attracted worldwide attention in recent years. Problems such as low rate of accuracy and poor self-adaptability still exist in traditional diagnosis. In order to solve these problems, an AdaBoost-SVM classification algorithm, combined with the cluster boundary sampling preprocessing techniques (CBS-AdaBoost-SVM), is proposed in this paper for the early diagnosis of breast cancer. The algorithm uses machine learning method to diagnose the unknown image data. Moreover, not all of the characteristics play positive roles for classification. To address this issue the paper delete redundant features by using Rough set attribute…reduction algorithm based on the genetic algorithm (GA). The effectiveness of the proposed methods are examined on DDSM by calculating its accuracy, confusion matrix, and receiver operating characteristic curves, which give important clues to the physicians for early diagnosis of breast cancer.
Show more
Keywords: Computer-aided diagnosis, image data mining, support vector machine, clustering sampling
Abstract: Cognitive dysfunction is a common feature of Parkinson's disease (PD). Recent research has focused on the detection and management of subjective memory impairment (SMI) as the stage that precedes mild cognitive impairment (MCI). Nevertheless, few clinical studies have biomarkers of SMI in PD. Therefore, this study was designed to investigate differences in perfusion brain SPECT between PD with SMI (PD+SMI) and PD without SMI (PD-SMI) to identify a potential prodromal biomarker of progression to dementia in patients with PD. In this study, 30 PD patients with SMI and 24 PD patients without SMI have been recruited. All subjects underwent perfusion…brain SPECT and neuropsychological testing. Brain SPECT images were analyzed by using the SPM program and comparing between patients with PD+SMI and PD-SMI. The PD+SMI and PD-SMI groups did not differ in any neuropsychological tests, except for MMSE. Despite a significant difference in MMSE scores, all scores of both groups were in the normal range. Brain SPECT analysis of PD+SMI patients showed hypoperfusion in the frontal and inferior temporal regions, anterior cingulate and thalamus compared with PD-SMI patients. This pilot study investigated the role of decreased brain perfusion SPECT findings in PD+SMI patients compared with PD-SMI patients as a predictive biomarker of pre-dementia as the stage that precedes MCI in PD. Larger, prospective studies are warranted for further investigation of the pathophysiology of neuronal systems during cognitive decline.
Show more
Abstract: In this study, the change of tumors' chemical composition in the temperature range of 20~70°C is quantified for photothermal tumor therapy by photoacoustic spectroscopy (PAS) with the wavelengths of 700~1000 nm. Based on the measured photoacoustic signals, two absorption peaks at the wavelengths of 750nm and 950nm are identified. It is also observed that high temperature (>55°C) is able to induce the physical and chemical degeneration of tumors. According to the in vitro tests, a new chemical species, met-hemoglobin, which is absent in normal blood, is generated at high temperature with enhanced near-infrared absorption.
Abstract: Murine induced colon cancer has been used to demonstrate that Second Harmonic Generation (SHG) microscopy images, combined with Two-Photon Excitation Fluorescence (TPEF) and specific quantization scoring methods allow distinguishing early alterations in colon mucosa. TPEF was used only to identified crypts and submucosa regions, whereas the image analysis was used to get quantitative data (Integrated Intensity and Aspect Ratio scoring) of different cancer stages. The submucosa amount of collagen fibers was significant and their orientation suffering proportional changes with the development of the pathological processes. Both after the fourth and eighth weeks after colon cancer induction, integrated intensity and aspect…ratio values have shown significant statistical differences compared with control samples. Thus, SHG microscopy has proved to be a useful quantitative tool to highlight early changes of submucosa and the progression of these through the cancer development.
Show more
Keywords: Colon cancer, early detection, second harmonic generation, two-photon excitation fluorescence
Abstract: Prevention of pressure sores remains a significant problem confronting spinal cord injury patients and the elderly with limited mobility. One vital aspect of this subject concerns the development of cushions to decrease pressure ulcers for seated patients, particularly those bound by wheelchairs. Here, we present a novel cushion system that employs interface pressure distribution between the cushion and the buttocks to design custom contoured foam cushion. An optimized normalization algorithm was proposed, with which interface pressure distribution was transformed into the carving depth of foam cushions according to the biomechanical characteristics of the foam. The shape and pressure-relief performance of…the custom contoured foam cushions was investigated. The outcomes showed that the contoured shape of personalized cushion matched the buttock contour very well. Moreover, the custom contoured cushion could alleviate pressure under buttocks and increase subjective comfort and stability significantly. Furthermore, the fabricating method not only decreased the unit production cost but also simplified the procedure for manufacturing. All in all, this prototype seat cushion would be an effective and economical way to prevent pressure ulcers.
Show more
Abstract: The purpose of this study was to assess gender-related distinction in the performance of Cushing's disease (CD) regarding clinical features, radiological findings, neurological and endocrine status, surgical outcome, and quality of life in Han Chinese. A retrospective study was conducted on 87 patients treated by trans-sphenoidal surgery, between 2006 and 2011, at a single treatment center in Shandong Provincial Hospital, China. Features of CD were compared and quality of life was analyzed between genders. The female-to-male ratio was 2.78: 1. Results showed that men have a younger age of diagnosis (P<0.001), a larger adenoma diameter (P<0.001), and a higher invasion…rate (P=0.032) and apoplexy rate (P=0.04) than women. To be specific, compared with women, men are more prone to suffering from osteoporosis, hypokalemia, sexual dysfunction, and hypertension (P<0.05), have significantly higher preoperative and postoperative (six months after surgery) cortisol levels (P<0.001, P=0.003) and a higher recurrence rate (30.43% vs. 7.81%; P=0.028). No significant differences were seen in the CushingQoL scores between genders. Therefore, male patients with CD need more careful and long-term follow-up than female patients.
Show more
Abstract: Heart disease has become the number one killer of human health, and its diagnosis depends on many features, such as age, blood pressure, heart rate and other dozens of physiological indicators. Although there are so many risk factors, doctors usually diagnose the disease depending on their intuition and experience, which requires a lot of knowledge and experience for correct determination. To find the hidden medical information in the existing clinical data is a noticeable and powerful approach in the study of heart disease diagnosis. In this paper, sparse logistic regression method is introduced to detect the key risk factors using…L1/2 regularization on the real heart disease data. Experimental results show that the sparse logistic L1/2 regularization method achieves fewer but informative key features than Lasso, SCAD, MCP and Elastic net regularization approaches. Simultaneously, the proposed method can cut down the computational complexity, save cost and time to undergo medical tests and checkups, reduce the number of attributes needed to be taken from patients.
Show more
Abstract: In this paper, a convenient and noninvasive scanning imaging method using microwave frequency band for abnormal subepidermal tissues detection is proposed in the aim to improve diagnosis and prognosis in clinical environments. This method is based on the reflective detection technology with coaxial probe that is used to measure the dielectric properties of tissues. An improved equivalent circuit and simulated annealing algorithm (SA) were used in this work to analyze the dielectric properties of tissues. Computational simulations incorporating a simplified model of subcutaneous hemorrhage described in this work were used to evaluate this method. The dielectric properties data of tissues…in the model of simulation is derived from the literature. The simulation results demonstrated the potential of this method to detect abnormal subepidermal tissues conveniently and expose them in the image accurately.
Show more
Abstract: Near-infrared spectroscopy (NIRS) was used to investigate the cerebral oxygenation of Moyamoya and healthy subjects. Continuous recordings of NIRS signals for 20 min (20 min signals) were obtained from 17 healthy subjects (age: 37.4±11.3) and 17 Moyamoya subjects (age: 40.1±11.2). Spectral analysis based on wavelet transformation identified five frequency intervals (I, 0.0095 Hz to 0.02 Hz; II, 0.02 Hz to 0.06 Hz; III, 0.06 Hz to 0.15 Hz; IV, 0.15 Hz to 0.40 Hz; and V, 0.40 Hz to 2.00 Hz) in the 20 min signals and three frequency intervals (III, 0.06 Hz to 0.15 Hz; IV, 0.15 Hz to…0.40 Hz; and V, 0.40 Hz to 2.00 Hz) in the 3 min signals (the first 3 min signals were continuously extracted from the 20 min signals). Significant differences (p < 0.05) were found in frequency intervals III and V. The former exhibited the myogenic activity of smooth muscle inside the blood vessels in both 20 min and 3 min signal analyses; the latter showed hemodynamic oscillation caused by heart pumping. This finding agrees with the vascular pathological changes in Moyamoya disease. As a potential screening method for Moyamoya disease, the simple threshold method exhibited 73.5% accuracy.
Show more
Abstract: Shoulder instability is a major threat to people's daily life. Many patients suffer from shoulder instability such as the loss of the glenoid and humeral head. In clinical practice, an accurate 3D structure estimation of damaged joints is necessary to diagnose and treat bone defects. This study quantifies osteoarticular defects through the modeling and visualization of osteoarticular structures. An improved algorithm to extract the 3D structure of the bones is proposed. The bone contour is then automatically extracted using prior shape and gray scale intensity distribution of joint CT images. Joint structures with mirror symmetry are matched using the Iterative…Closest Point registration algorithm. Osteoarticular defects can be quantified on the basis of the symmetric information of the bones. Experimental results demonstrate that the proposed method can effectively segment the joint structures from the CT image. In addition, the proposed mirror symmetrical method can effectively estimate osteoarticular defects.
Show more
Abstract: Intensity-Modulated Radiation Therapy (IMRT) mathematically forms a large-scale optimization problem. The development of an IMRT plan is computationally expensive resulting in time-consuming, inefficient, and difficult to develop high-quality IMRT plans. By combining prior knowledge with proposed novel measures derived from both Overlap Volume Histogram (OVH) descriptors and Dose Volume Histograms (DVHs), a novel quality control method for IMRT planning is proposed to assure the high quality of IMRT plan. Clinical approved nasopharyngeal IMRT plans were employed for the experiments, where the reference plan is firstly retrieved from IMRT plan database for each query case by using measures derived from both…OVH descriptors and DVHs. Then the DVHs of the reference plan are served as additional goals for the IMRT plan re-optimization. The experimental results show that the proposed method can effectively pick out those IMRT plans, whose quality could be improved substantially (i.e. the doses of their Clinical Targets Volume (CTV) could be effectively increased) and the dose of their Organs at Risk (OARs) could be reduced after the IMRT plan has being re-optimized. In conclusion, the proposed methods can effectively guarantee the high quality of the IMRT planning.
Show more
Abstract: The celiomesenteric trunk is a rare anomaly characterized by a common origin of the celiac axis and superior mesenteric artery from the aorta, which accounts for less than 1% of all celiac artery anomalies, so the aneurysm occurred in such trunk is even rarer. There have been few reports on how to diagnose and deal with such malformed celiomesenteric trunk aneurysms till now. This paper tries to summarize the experience of how to expose and excise such kind of aneurysm according to the seven cases' data. The clinic data were collected retrospectively. There were seven cases with celiomesenteric trunk aneurysm…from February 2000 to February 2013, including 5 males and 2 females aged 35~62. The operations were done including aneurysm resection and vascular reconstruction under general anesthesia. The operated patients were followed-up at the sixth month and each year post operation. The vascular stomas were detected or examined by Color Doppler Sonography, spiral Computed Tomography angiography (SCTA). The seven operated patients were cured and discharged from hospital, and they were followed up for 3~10 years (mean time 5 years), with four patients being followed up longer than 5 years. No sign of intestinal ischemia or hepatic ischemia or splenic ischemia was found, and no image of anastomosis stricture or stenosis was found during the follow-up. Five patients are alive now while two patients were dead, with one dying of large area myocardial infarction unexpectedly at 6 years post operation and the other dying of cerebral infarction abruptly at 4 years post operation. It is an effective and safe method to treat the celiomesenteric trunk aneurysm by using by-pass operation with artificial blood vessels, originating from inferior kidney aorta to visceral arteries including hepatic artery, splenic artery and superior mesenteric artery. Its short-term and middle-term effects are relatively better.
Show more
Keywords: Celiomesenteric trunk, superior mesenteric artery, celiac trunk, aneurysm, operation
Abstract: People with Multiple Sclerosis (MS) need regular physical activities along with medical treatment despite their ability or disability level. However, poorly performed exercises could aggravate muscle imbalances and worsen their health. The goal of our work is to create a comprehensive system, encompassing a face-to-face sessions performed by MS patients one day a week at the medical center with exercises at home the rest of the week through a web platform in combination with a tracking tool to analyze the position of patients during exercise and correct them in real-time. The whole system is currently testing during six months with…ten participants, five persons with MS and 5 professionals related with MS. Two tests, the Functional Independence Measure and the Berg Balance Scale will be act as a barometer for measuring the degree of independence obtained by the people with MS and also the validity of the whole system as a rehabilitation tool. Preliminary results about the usability of the system using SUS scale, 72 and 76 points over 100 (patients and professionals respectively), demonstrate that our system is usable for both patients and professionals.
Show more
Keywords: Multiple Sclerosis, telerehabilitation, web application, verticality analysis
Abstract: This paper proposes the design and implementation of a low-voltage and low-power body sensor node based on the IEEE 802.15.4 standard to collect electrocardiography (ECG) and photoplethysmography (PPG) signals. To achieve compact size, low supply voltage, and low power consumption, the proposed platform is integrated into a ZigBee mote, which contains a DC-DC booster, a PPG sensor interface module, and an ECG front-end circuit that has ultra-low current consumption. The input voltage of the proposed node is very low and has a wide range, from 0.65 V to 3.3 V. An RF energy harvester is also designed to charge the…battery during the working mode or standby mode of the node. The power consumption of the proposed node reaches 14 mW in working mode to prolong the battery lifetime. The software is supported by the nesC language under the TinyOS environment, which enables the proposed node to be easily configured to function as an individual health monitoring node or a node in a wireless body sensor network (BSN). The proposed node is used to set up a wireless BSN that can simultaneously collect ECG and PPG signals and monitor the results on the personal computer.
Show more
Keywords: Body sensor network, electrocardiography, photoplethysmography, low-power node, radio frequency energy harvester
Abstract: This paper describes a study dealing with a technological solution to measure gait quality in people suffering from multiple sclerosis (MS) by selecting objective parameters that focus on their step. Android mobile technology, online services and four wireless pressure sensors are used in concert for this purpose. The objective of this work is the early detection of deterioration of the patient so that a physician can quickly intervene. Tests were carried out on a group of 8 persons with MS, and these results were compared with a control a group of 6 healthy participants. The results indicated a statistical difference…in 7 of 40 general step features, with a minimum σ=0.013 and a maximum σ=0.029. These characteristics showed differences between first and fifth metatarsals for each group. It was concluded that these parameters can be used to evaluate gait degeneration in people with MS and that further information could be obtained from measurements with sensors to monitor activities such as bending and inertial sensors.
Show more
Abstract: This paper presents a shoe-integrated sensor device which collects objective information concerning the gait quality in patients' physical rehabilitation. It involves four pressure sensors, two bending sensors, an ultrasonic sensor and a 9dof IMU, an Inertial Measurement Unit with three accelerometers, three gyroscopes and three magnetometers. The device includes a SDRAMPS with the aim of storing the information for long periods of time. The collected data can be sent to the server for later visualization by the specialist and the patient on a web platform. An interface shows the data in real time, allowing it to verify the connections and…to check different movements.
Show more
Abstract: Promising development in the light emitting diode (LED) technology has spurred the interest to adapt LED for both illumination and data transmission. This has fostered the growth of interest in visible light communication (VLC), with on–going research to utilize VLC in various applications. This paper presents a mobile–health monitoring system, where healthcare information such as biomedical signals and patient information are transmitted via the LED lighting. A small and portable receiver module is designed and developed to be attached to the mobile device, providing a seamless monitoring environment. Three different healthcare information including ECG, PPG signals and HL7 text information…is transmitted simultaneously, using a single channel VLC. This allows for a more precise and accurate monitoring and diagnosis. The data packet size is carefully designed, to transmit information in a minimal packet error rate. A comprehensive monitoring application is designed and developed through the use of a tablet computer in our study. Monitoring and evaluation such as heart rate and arterial blood pressure measurement can be performed concurrently. Real–time monitoring is demonstrated through experiment, where non–hazardous transmission method can be implemented alongside a portable device for better and safer healthcare service.
Show more
Abstract: Recently, several medical devices that use wireless communication are under development. In this paper, the small size frequency shift keying (FSK) transmitter and a monofilar antenna for the capsule endoscope, enabling the medical device to transmit VGA-size images of the intestine. To verify the functionality of the proposed wireless communication system, computer simulations and animal experiments were performed with the implemented capsule endoscope that includes the proposed wireless communication system. Several fundamental experiments are carried out using the implemented transmitter and antenna, and animal in-vivo experiments were performed to verify VGA image transmission.
Abstract: This paper presents the results of research that applies cognitive therapies associated with memory and mathematical problem-solving in elderly people. The exercises are programmed in an iPad and can be performed both from the Tablet and in an interactive format with a LEGO robot. The system has been tested with 2 men and 7 women over the age of 65 who have slight physical and cognitive impairment. Evaluation with the SUS resulted in a mean of 48.45 with a standard deviation of 5.82. The score of overall satisfaction was 84.37 with a standard deviation of 18.6. Interaction with the touch…screen caused some usability problems due to the elderly people's visual difficulties and clicking accuracy. Future versions will include visualization with more color contrast and less use of the keyboard.
Show more
Keywords: iPad, cognitive rehabilitation, objective-C, system usability scale (SUS)
Abstract: The discrete-time fractional Gaussian noise (DFGN) has been proven to be a regular process. Therefore, an autoregressive (AR) model of an infinite order can describe DFGN based on Wold and Kolmogorov theorems. A fast estimation algorithm on the Hurst exponent of DFGN or discrete-time fractional Brownian motion (DFBM) has been proposed, but the algorithm did not consider the order selection of AR model. Recently, a Hurst exponent estimator based on an AR model with six existing methods of order selection has been proposed to raise the accuracy of estimating the Hurst exponent. Although the estimation accuracy has been confirmed to…be better than the one without order selection, the estimator still requires computing all parameter sets through the Levinson algorithm. In order to lower computational cost, this paper proposes an efficient method of order selection, simply called data induction, which uses simulation data to induce an appropriate threshold of terminating the Levinson algorithm before computing all parameter sets. Experimental results show that the proposed data-induction method has a competitive advantage over six existing methods of order selection in terms of lowering computational cost and raising the accuracy.
Show more
Abstract: This paper presents the single channel speech enhancement system using subband Kalman filtering by estimating optimal Autoregressive (AR) coefficients and variance for speech and noise, using Weighted Linear Prediction (WLP) and Noise Weighting Function (NWF). The system is applied for normal and Oesophageal speech signals. The method is evaluated by Perceptual Evaluation of Speech Quality (PESQ) score and Signal to Noise Ratio (SNR) improvement for normal speech and Harmonic to Noise Ratio (HNR) for Oesophageal Speech (OES). Compared with previous systems, the normal speech indicates 30% increase in PESQ score, 4 dB SNR improvement and OES shows 3 dB HNR…improvement.
Show more
Keywords: Kalman filter, autoregressive, speech enhancement, weighted linear prediction
Abstract: Biomedical magnetic induction measurement is a promising method for the detection of intracerebral hemorrhage (ICH), especially in China. Aiming at overcoming the problem of low sensitivity, a magnetic induction sensor is chosen to replace the conventional sensors. It uses a two-arm Archimedean spiral coil as the exciter and a circular coil as the receiver. In order to carry out high-fidelity simulations, the Chinese head model with real anatomical structure is introduced into this novel sensor for the first time. Simulations have been carried out upon early stage ICH measurements. By calculating the state sensitivity and time sensitivity of the perturbation…phase of two types of sensors using the electromagnetic software, we conclude that the primary signal received can be largely reduced using the novel sensor, which could effectively increase the time and state sensitivity simultaneously.
Show more
Keywords: Intracerebral hemorrhage (ICH), magnetic induction measurement, sensor sensitivity, two-arm archimedean spiral coil (TAASC), Chinese head model
Abstract: This paper proposes a bio-potential measurement apparatus including a wireless device for transmitting acupuncture bio-potential information to a remote control station for health conditions analysis and monitor. The key technology of this system is to make replaceable foam-rubber cushions, double-side conducting tapes, chip and antenna on the radio frequency identification (RFID) tag. The foam-rubber cushions can be wetted with salt-water and contact with the acupuncture points to reduce contact resistance. Besides, the double-side conducting tapes are applied to fix foam-rubber cushions. Thus, one can peel the used cushions or tapes away and supply new ones quickly. Since the tag is…a flexible plastic substrate, it is easy to deploy on the skin. Besides, the amplifier made by CMOS technology on RFID chip could amplify the signals to improve S/N ratio and impedance matching. Thus, cloud server can wirelessly monitor the health conditions. An example shows that the proposed system can be used as a wireless health condition monitor, the numerical method and the criteria are given to analyze eleven bio-potentials for the important acupunctures of eleven meridians on a person's hands and legs. Then a professional doctor can know the performance of an individual and the cross-linking effects of the organs.
Show more
Keywords: RFID tag, bio-potential, flexible substrate, wireless health monitor, wetted replaceable foam-rubber cushion
Abstract: The piezoelectric biosensor have been widely used in ultra-small mass detection of biomolecular, based on PZT piezoelectric material can create a variety of compositions geometrically; it could widely develop a high-frequency resonator and measure the change of the slightest mass while improve the limited detection simultaneously. Therefore, the piezoelectric biosensor of this study was fabricated by a spin-coating method and backside etching process for improving the characteristic of piezoelectric biosensor. The result exhibited that the 250 μm × 250 μm working size has the most favorable piezoelectric characteristic. The tunability was approximately 38.56 % and it showed that reducing the…substrate thickness could obtain a clear resonance signal in a range of 60 to 380 MHz. In theory calculated for gravimetric sensing, it could achieve 0.1 ng sensing sensitivity. In gravimetric sensing, the sensing range was between 50,000~100,000 CFU/ml. Sensing range was lower in clinical urinary tract infection (100,000 CFU/ml), thus demonstrating its usefulness for preventive medicine. It can understand the piezoelectric sensor of this study has potential application in the future for biomedical gravimetric sensing.
Show more
Keywords: Lead zirconate titanate (PZT), piezoelectric, biosensor, resonance-frequency, escherichia coli (E. coli)
Abstract: Pulse wave contains much information on a cardiovascular system. Pulse wave variability during exercise is of great significance as it reflects more information combining with pulse wave under stationary state. This paper studied the morphology variability of radial pulse wave during exercise. Radial pulse waves were collected from 30 subjects with two pressure pulse sensors worn at the wrists of the right and left hands, respectively. Electrocardiography (ECG) was also detected synchronously. After data preprocessing and feature point extraction, the variability of several parameters of pulse wave and ECG were analyzed. It is notable that pulse rate (PR) and heart…rate (HR) change synchronously. During the exercise period, both systolic phase and diastolic phase of a radial pulse shorten but the latter is more obvious. The amplitude of the dicrotic notch decreases and even turns negative. Aligning the radial pulse waveforms together, the radial pulse waveforms prior to, during and after exercise coincide with each other except for some details like the tidal wave which fades away during exercise.
Show more
Abstract: Sensorimotor control dysfunction or dyskinesia is a hallmark of neuromuscular impairment in children with cerebral palsy (CP), and is often implicated in reaching and grasping deficiencies due to a neuromuscular imbalance between the triceps and biceps. To mitigate such muscle imbalances, an innovative electromyography (EMG)-virtual reality (VR) biofeedback system were designed to provide accurate information about muscle activation and motivation. However, the clinical efficacy of this approach has not yet been determined in children with CP. The purpose of this study was to investigate the effectiveness of a combined EMG biofeedback and VR (EMG-VR biofeedback) intervention system to improve muscle…imbalance between triceps and biceps during reaching movements in children with spastic CP. Raw EMG signals were recorded at a sampling rate of 1,000 Hz, band-pass filtered between 20–450 Hz, and notch-filtered at 60 Hz during elbow flexion and extension movements. EMG data were then processed using MyoResearch Master Edition 1.08 XP software. All participants underwent both interventions consisting of the EMG-VR biofeedback combination and EMG biofeedback alone. EMG analysis resulted in improved muscle activation in the underactive triceps while decreasing overactive or hypertonic biceps in the EMG-VR biofeedback compared with EMG biofeedback. The muscle imbalance ratio between the triceps and biceps was consistently improved. The present study is the first clinical trial to provide evidence for the additive benefits of VR intervention for enhancing the upper limb function of children with spastic CP.
Show more
Abstract: In this study, a tactile stimulator that could separately or simultaneously display the vibrotactile and pressure sense was developed. The developed system consisted of a control unit, a drive unit, and an actuator, and can be operated with PC or manually. This system quantitatively controls the stimulation parameters such as the stimulation intensity, duration, frequency, and stimulation type. A preliminary electroencephalogram (EEG) experiment for three types of stimulation (vibrotactile, pressure sense, vibrotactile + pressure sense) highlights that the system could be used in complex tactile cognitive studies. An event-related desynchronization (ERD) and synchronization (ERS) were measured at the area of…C3 and C4 for all three types of stimulation, and a clear response was identified in the contralateral somatosensory area from the brain topology. Therefore, it is expected that this system could be widely used in single and complex human tactile cognition and perception studies for vibrotactile and pressure sensation.
Show more
Abstract: Demyelination is part of the cascading secondary injury after the primary insult and contributes to the loss of function after spinal cord injury (SCI). Oligodendrocyte precursor cells (OPCs) are the main remyelinating cells in the central nervous system (CNS). We explored whether oscillating field stimulation (OFS) could efficiently promote OPC differentiation and improve remyelination after SCI. SD rats with SCI induced by the Allen method were randomly divided into two groups, the SCI+OFS group and SCI group. The former group received active stimulator units and the latter group received sham (inoperative) stimulator units. Additionally, rats that only received laminectomy were…referred as the sham group. The electric field intensity was 600μV/mm, and the polarity was alternated every 15 minutes. The results showed that the SCI+OFS rats had significantly less demyelination and better locomotor function recovery after 12-weeks treatment. The OFS treatment significantly increased the number of Gal C-positive OPCs after 2-weeks treatment. Furthermore, these rats had higher protein expression of oligodendroglial transcription factors Olig2 and NKx2.2. These findings suggest OFS can promote locomotor recovery and remyelination in SCI rats and this effect may be related to the improved differentiation of OPCs in the spinal cord.
Show more
Keywords: Oligodendrocyte precursor cells, remyelination, oscillating field stimulation, spinal cord injury, rat
Abstract: Recent studies have shown that working memory (WM) performance can be improved by intensive and adaptive computerized training. Here, we explored the WM training effect using Electroencephalography (EEG) neurofeedback (NF) in normal young adults. In the first study, we identified the EEG features related to WM in normal young adults. The receiver operating characteristic (ROC) curve showed that the power ratio of the theta-to-alpha rhythms in the anterior-parietal region, accurately classified a high percentage of the EEG trials recorded during WM and fixation control (FC) tasks. Based on these results, a second study aimed to assess the training effects of…the theta-to-alpha ratio and tested the hypothesis that up-regulating the power ratio can improve working memory behavior. Our results demonstrated that these normal young adults succeeded in improving their WM performance with EEG NF, and the pre- and post-test evaluations also indicated that WM performance increase in experimental group was significantly greater than control groups. In summary, our findings provided preliminarily evidence that WM performance can be improved through learned regulation of the EEG power ratio using EEG NF.
Show more
Keywords: Electroencephalography, neurofeedback, working memory, power spectrum, self-regulation
Abstract: The aim of the present study was to research the role of nitric oxide (NO) as a mediator of alpha (α)-asarone effect at the pentylenetetrazol (PTZ)-induced epileptiform discharge in rat. α-Asarone that was injected intraperitoneally twenty minutes before PTZ injection suppressed the clonic discharge effectively and the significant actions lasted for 30 min with no change of clonic amplitude. Administration of α-asarone did not influence interictal discharge. Four kinds of NO regulators were administered, including non-selective NG-nitro-L-arginine methyl ester (L-NAME), selective neuronal nitric oxide synthase (nNOS) inhibitor, 7-nitroindazole (7-NI), inducible nitric oxide synthase (iNOS) inhibitor, aminoguanidine (AG) and NO substrate,…L-arginine (ARG) and their influence on the actions of α-asarone were studied, and all of the regulators were administered fifteen minutes before α-asarone injection. L-NAME and 7-NI reversed the anticlonic activity of α-asarone, and a significant increase of clonic activity was induced by L-NAME later in L-NAME + .α-asarone + PTZ group. There were no significant differences between AG + α-asarone + PTZ and α-asarone + PTZ group. L-ARG played a dual role in this study. It aggravated clonic discharge in the early stage but relieved interictal discharge in the late stage compared with PTZ group alone, and the beneficial effect of α-asarone was also reversed. All the above results suggest that nNOS/NO pathway mediates the anticonvulsant effect of α-asarone, and NO played a biphasic role in PTZ modeling process, while iNOS was unrelated to the inhibition effect of α-asarone on PTZ induced epileptiform activity.
Show more
Abstract: Bioelectrical impedance phase angle has been recommended as a tool to assess nutrition state, but there are no measuring devices have been specially designed for hospital residents. In this study, a system was established for the measurement of bioelectrical impedance phase angle. The electrical composition, calculation method and measuring method of this system are presented in this paper. Experiments showed excellent performance of this system in measuring impedance made of resistors and capacitors. The designed system was also used to measure the bioelectrical impedance phase angle of both healthy subjects and patients with malnutrition, and the results demonstrated that the…phase angle of patients with malnutrition is lower than that of healthy subjects (P < 0.01 for male and P < 0.05 for female). These results suggest that phase angle has the potential to be a useful tool for the quantitative assessment of nutritional status.
Show more
Keywords: Phase angle, bioelectrical impedance, nutritional status
Abstract: Classification methods are a crucial direction in the current study of brain-computer interfaces (BCIs). To improve the classification accuracy for electroencephalogram (EEG) signals, a novel KF-PP-SVM (kernel fisher, posterior probability, and support vector machine) classification method is developed. Its detailed process entails the use of common spatial patterns to obtain features, based on which the within-class scatter is calculated. Then the scatter is added into the kernel function of a radial basis function to construct a new kernel function. This new kernel is integrated into the SVM to obtain a new classification model. Finally, the output of SVM is calculated…based on posterior probability and the final recognition result is obtained. To evaluate the effectiveness of the proposed KF-PP-SVM method, EEG data collected from laboratory are processed with four different classification schemes (KF-PP-SVM, KF-SVM, PP-SVM, and SVM). The results showed that the overall average improvements arising from the use of the KF-PP-SVM scheme as opposed to KF-SVM, PP-SVM and SVM schemes are 2.49%, 5.83 % and 6.49 % respectively.
Show more
Keywords: Kernel fisher, posterior probability, support vector machine, brain computer interface, common spatial pattern
Abstract: The electrode polarization effects on bioelectrical impedance measurement at low-frequency cannot be ignored. In this paper, the bioelectrical data of mice livers are measured to specify the polarization effects on the bio-impedance measurement data. We firstly introduce the measurement system and methodology. Using the depolarization method, the corrected results are obtained. Besides, the specific effects of electrode polarization on bio-impedance measurement results are investigated using comparative analysis of the previous and posterior correction results from dielectric spectroscopy, Cole-Cole plot, conductivity and spectroscopy of dissipation tangent. Experimental results show that electrode polarization has a significant influence on the characteristic parameters of…mouse liver tissues. To be specific, we see a low-frequency limit resistance R0 increase by 19.29%, a reactance peak XP increase by 8.50%, a low-frequency limit conductivity Kl decrease by 17.65% and a dissipation peak tangent decrease by 160%.
Show more
Abstract: The microphone in a fully implantable hearing device (FIHD) is generally implanted under the skin covering the temporal bone. However, the implanted microphone can be affected by the skin, which causes both sound attenuation and distortion, particularly at high frequencies. As the degree of attenuation and distortion through the skin is severe, speech quality evaluation parameters are needed for the received signal when designing an implantable microphone. However, the performance of most implantable microphones is only assessed based on the sensitivity and frequency response. Thus, practical indicators based on human auditory characteristics are needed for an objective evaluation of the…performance of implantable microphones. In this study, a subcutaneously implantable microphone was designed, and its frequency response investigated using an in vivo experiment. Plus, to evaluate the objective indicators, the speech quality of the signals measured by the implanted microphone was calculated using a MATLAB program, and the indicators compared before and after implantation.
Show more
Keywords: Implantable microphone, in vivo experiment, speech quality score, fully implantable hearing devices
Abstract: Injury potential, a significant index of spinal cord injury (SCI), is generated by the movement of extracellular ions. It can be compensated through applied direct current (DC) stimulation, which prevents the influx of the free calcium, and eventually reduces the development of secondary injury. Therefore, the compensation of injury potential is beneficial to the repairing of the function of spinal cord. The compensation effect can be evaluated by whether the magnitudes of longitudinal electric fields (EFs) are compensated to zero. However, there have been no established criteria to determine the distribution and shape of stimulating electrodes. In this study, in…order to optimize the stimulating electrodes, a finite element model (FEM) of rat spinal cord was developed, and the EFs changes induced by electrodes of different sizes, shapes and locations after SCI were calculated. All the designed configurations of electrodes were able to compensate injury potential, but the resultant compensation effects vary. Pin and disc electrodes produced uneven EFs, while ring electrodes produced uniformly distributed EFs. Moreover, large ring electrodes can compensate the longitudinal EFs almost to zero with relatively low current density (0.55 μA/mm2 ) applied. These results provide a basis for the determination of electrical stimulation parameters in the compensation of injury potential.
Show more
Keywords: Direct current stimulation, finite element model, spinal cord injury, electric fields
Abstract: In this study, the bandwidth of the filter-based fatigue index was determined by the comparison of optimized cut-off frequencies in different inter-electrode distances. Sixty-one subjects participated in isometric knee extension, isotonic ankle dorsiflexion, and isotonic elbow extension exercises. Electromyography (EMG) signals were obtained from right rectus femoris, triceps brachii, and tibialis anterior muscles during exercises. The filter-based fatigue index was compared with mean root-mean-square values, median frequency, Dimitrov spectral index, and Gonzalez-Izal wavelet index. Optimized cut-off frequencies of the high-pass filter for three different exercises and three different inter-electrode distances were about 350 Hz. Results from this study support that…around 350 Hz high-pass filter could be useful to determine cut-off frequency for fatigue prediction in general purposes.
Show more
Abstract: Clustering is considered one of the most powerful tools for analyzing gene expression data. Although clustering has been extensively studied, a problem remains significant: iterative techniques like k-means clustering are especially sensitive to initial starting conditions. An unreasonable selection of initial points leads to problems including local minima and massive computation. In this paper, a spatial contiguity analysis-based approach is proposed, aiming to solve this problem. It employs principal component analysis (PCA) to identify data points that are likely extracted from different clusters as initial points. This helps to avoid local minima, and accelerates the computation. The effectiveness of the…proposed approach was validated on several benchmark datasets.
Show more
Abstract: The transcriptional regulation of cellular functions is carried out by the overlapping functional modules of a complex network. In this paper, a statistical approach for detecting functional modules in the transcriptional regulatory networks (TRNs) is studied. The proposed method defines modules as groups of links rather than nodes since nodes naturally belong to more than one module. Furthermore, the proposed algorithm is evaluated on the Escherichia coli TRN. The experimental results demonstrate that it detected a suitable number of overlapping modules that were biologically meaningful without any prior knowledge about the modules.
Abstract: Among human influenza viruses, strain A/H3N2 accounts for over a quarter of a million deaths annually. Antigenic variants of these viruses often render current vaccinations ineffective and lead to repeated infections. In this study, a computational model was developed to predict antigenic variants of the A/H3N2 strain. First, 18 critical antigenic amino acids in the hemagglutinin (HA) protein were recognized using a scoring method combining phi (ϕ) coefficient and information entropy. Next, a prediction model was developed by integrating multiple linear regression method with eight types of physicochemical changes in critical amino acid positions. When compared to other three known…models, our prediction model achieved the best performance not only on the training dataset but also on the commonly-used testing dataset composed of 31878 antigenic relationships of the H3N2 influenza virus.
Show more
Keywords: Influenza A virus, H3N2, antigenic variant, multiple linear regression, physicochemical properties
Abstract: Microorganisms interact with each other within a community. Within the same community, some microorganisms tend to co-exist, whereas some others tend to avoid each other. The association among microorganisms can be revealed by computing the correlation between their abundance patterns that are measured through metagenomic sequencing across multiple communities. In this paper, we built an association network among microorganisms from the human oral microbiome. To improve its accuracy, we adopted a network deconvolution algorithm to filter out indirect associations, and we used an ensemble of three correlation measures to filter out the false-positive associations. When applying on the metagenomic data…from human oral samples, experimental results showed that phylogenetically close microorganisms formed highly correlated network clusters. Additionally, most of the identified mutually exclusive associations were related to the order Lactobacillales.
Show more
Keywords: Association network, correlation, microbiome, network deconvolution
Abstract: The objective of this study is to evaluate whether the accumulation model developed by Zarfl et al. (2008) could be used to predict the minimal inhibitory concentration (MIC) of a group of antibacterial fluoroquinolones (FQs) for Escherichia coli (E. coli). Our model, which is based on the “Fick-Nernst-Planck” equation and the permeability of the neutral and charged species as well as the physicochemical parameters of the FQs, could predict 1/MIC9 0 using a linear function. It is envisaged that in the drug development projects of new FQs, the accumulation model described in this study could be utilized as an effective…tool to enable early assessment of MIC value using physiochemical parameters.
Show more
Abstract: The minimum error correction model is an important combinatorial model for haplotyping a single individual. In this article, triploid individual haplotype reconstruction problem is studied by using the model. A genetic algorithm based method GTIHR is presented for reconstructing the triploid individual haplotype. A novel coding method and an effectual hill-climbing operator are introduced for the GTIHR algorithm. This relatively short chromosome code can lead to a smaller solution space, which plays a positive role in speeding up the convergence process. The hill-climbing operator ensures algorithm GTIHR converge at a good solution quickly, and prevents premature convergence simultaneously. The experimental…results prove that algorithm GTIHR can be implemented efficiently, and can get higher reconstruction rate than previous algorithms.
Show more
Keywords: Triploid, haplotype, Single nucleotide polymorphism (SNP), the minimum error correction, genetic algorithm
Abstract: In order to assign appropriate baseline estimation algorithms to different fetal heart rate tracing, a method to evaluate the fetal heart rate (FHR) baseline combining with the fetal movement information was proposed. Fetal actography and tocography were used to extract the fetal movement information. The results showed that the combined method, where the fetal movement detection result was the union of results of actography and tocography, achieved a better performance with the highest sensitivity and an acceptable positive predictive value (PPV). Furthermore, the mean absolute errors (MAEs) of basal FHR values between the two algorithms and the expert were calculated…with respect to the duration coefficient of fetal movement. The results showed that the algorithm using empirical mode decomposition (EMD) and Kohonen neural network (KNN) had lower MAEs than a traditional linear baseline estimation algorithm as the duration coefficient increased. However, if the duration coefficient is below 0.2, the errors may be tolerant for the FHR baseline estimation by a linear baseline estimation algorithm, which indicates that different algorithms may be selected for FHR baseline estimation based on different duration coefficients of fetal movement.
Show more
Abstract: Microarray technologies offer practical diagnostic tools for cancer detection. One great challenge is to identify salient genes from the high dimensionality of microarray data that can directly contribute to the symptom of cancer. Interactions among genes have been recognized to be fundamentally important for understanding biological function. This paper proposes an interacting gene selection method for cancer classification by identifying useful interacting genes. The method firstly evaluates the interactivity degree of each gene according to the intricate interrelation among genes by cooperative game analysis. Then genes are selected in a forward way by considering both interactivity and relevance characters. Experimental…comparisons are carried out on four publicly available microarray data sets with three outstanding gene selection methods. Moreover a gene set enrichment analysis is also performed on the selected gene subset. The results show that the proposed method achieves better classification performance and enrichment score than other gene selection methods.
Show more
Keywords: Medical diagnosis, cancer classification, gene selection, information theory, cooperative game analysis