Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Purchase individual online access for 1 year to this journal.
Price: EUR 185.00Authors: Zhang, Guang | Zhang, Tao | Sun, Xiubin | Tang, Fang | Lin, Haiyan | Liu, Yanxun | Zhang, Chengqi | Xue, Fuzhong
Article Type: Research Article
Abstract: The association between whole blood viscosity (WBV) and metabolic syndrome (MetS) is still scarcely investigated in the population-based prospective cohort. We aim to explore the longitudinal effect of WBV on MetS, and to verify whether WBV measures can be used as early predictors for MetS. The longitudinal cohort consisted of 3,508 adults (2,350 males and 1,158 females) who visited the health check-up system twice. WBV were measured at four shear rate (200, 50, 10 and 1 s-1 ), and their values were classified into quartiles. Multivariate Cox models were used to estimate the adjusted hazard ratios (HRs) and 95% confidence …intervals (CIs) in men and women, respectively. A total of 444 (12.66%) incident MetS were observed at follow-up period. The incidences of MetS significantly increased with increasing quartiles of WBVs at all of the shear rate in men. After adjusting for baseline age, smoking, obesity, hypertension, hyperglycemia, and hyperlipidemia status, all of the WBV measures were significantly associated with incident MetS in men, and the HRs showed clear increasing trend across the quartiles of baseline WBVs. There were no significant association between WBVs and incident MetS in women. These findings suggest that MetS has a hemodynamic basis, and WBVs could be used as independent early predictor for MetS in men. Show more
Keywords: Whole blood viscosity, metabolic syndrome, prospective cohort
DOI: 10.3233/CH-15120
Citation: Clinical Hemorheology and Microcirculation, vol. 80, no. 1, pp. 1-8, 2022
Authors: Liu, Haifang | Zhu, Yuping | Jiao, Jie | Yuan, Jia | Pu, Tianning | Yong, Qiang
Article Type: Research Article
Abstract: The aim of this study was to assess the elasticity of Hashimoto’s thyroiditis in the different processes via supersonic ShearWave™ Elastography (SWE™). Quantitative information is delivered as Young’s modulus value expressed in kilo-Pascal (kPa). 30 healthy female and 30 healthy male individuals aging at 40±20 y had undergone conventional ultrasonography and SWE to determine the influence of gender on elasticity of thyroid. Also 60 female and 60 male patients (mean age, 40±20 y) with Hashimoto’s thyroiditis in different processes underwent conventional ultrasonography and SWE to determine the elasticity of thyroid in Hashimoto’s thyroiditis. Furthermore, the relationship between elasticity values and …thyroid peroxidase antibody (TPOAB) in the patients was investigated. We found significant impact of gender on elasticity values of healthy thyroids. Our study showed that increased elasticity values with statistical significance in hyperthyroidism stage, normal thyroid function stage and hypothyroidism were shown. Low degree relationship between elasticity values and TPOAB was found in 60 male patients. However, there was no such correlation in female patients. Show more
Keywords: ShearWave™ elastography, hashimoto’s thyroiditis, ultrasound imaging, elasticity
DOI: 10.3233/CH-170347
Citation: Clinical Hemorheology and Microcirculation, vol. 80, no. 1, pp. 9-16, 2022
Authors: Park, Seong Jun | Yoon, Jung | Seo, Hong Seog | Lim, Chae Seung
Article Type: Research Article
Abstract: BACKGROUND: Platelet function analysis is crucial in assessing the hemostatic status to evaluate congenital and acquired platelet function defects. The Anysis-200 analyzer is a new automated lab-on-a-chip-based platelet function analyzer. OBJECTIVE: We aimed to evaluate a new platelet function analyzing system, the Anysis-200 in comparison to the Platelet Function Analyzer (PFA)-200 in cardiac patients. METHODS: Citrated blood was collected from 174 patients who visited the Department of Cardiology. The Anysis-200 consists of two kits, the microchips with collagen and epinephrine-coated membrane (C/EPI) or adenosine diphosphate-coated membrane (C/ADP). Platelet clogging in the Anysis-200 is measured by the …blood migration distance obtained by a camera, which is compatible with the closure time in the PFA-200. We performed Anysis-200 and PFA-200 analyzers simultaneously and compared the results. RESULTS: The sensitivity and specificity of the Anysis-200 C/EPI kit in comparison to the PFA-200 C/EPI kit were 63.41% and 91.43%, respectively. Regarding the C/ADP kit, the sensitivity and specificity of the Anysis-200 were 58.97% and 74.29%, respectively. The agreement rate between the Anysis-200 and PFA-200 for C/EPI was 83.35% and 70.14% for C/ADP. CONCLUSIONS: The Anysis-200, which applies a novel method to detect platelet clogging, has shown moderate to fair agreement with the PFA-200. This test is potentially useful for screening cardiac patients with an abnormal platelet function. Show more
Keywords: Platelet function, Anysis-200 analyzer, PFA-200 analyzer
DOI: 10.3233/CH-190801
Citation: Clinical Hemorheology and Microcirculation, vol. 80, no. 1, pp. 17-24, 2022
Authors: Zhao, Meng | Zhu, Yunkai | Zhang, Yanhua | Yang, Xupeng | Duan, Yourong | Chen, Yaqing | Sun, Ying
Article Type: Research Article
Abstract: BACKGROUND: Molecular targeted contrast-enhanced ultrasound (CEUS) imaging is a potential imaging strategy to improve the diagnostic accuracy of conventional ultrasound (US) imaging. US contrast agents are usually micrometer-sized and non-target gas bubbles while nano-sized and targeted agents containing phase-shift materials absorb more attractions for their size and the liquid core and excellent molecular imaging effect. METHODS: PLGA12k -mPEG2k -NH2 , DSPE-mPEG2k and perfluorohexan (PFH) were used to construct a new targeted ultrasound contrast agent with CUB domain-containing protein 1 (CDCP1) receptor for the detection and diagnosis of prostate cancer. The potential of tumor-targeted nanoparticles (CDCP1-targeted perfluorohexan-loaded phase-transitional …nanoparticles, anti-CDCP1 NPs) as contrast agents for ultrasound (US) imaging was assessed in vitro . Moreover, studies on the cytotoxicity and the targeting ability of anti-CDCP1 NPs assisted by US were carried out. RESULTS: The results showed that anti-CDCP1 NPs had low cytotoxicity, and with the increasing of polymer concentration in anti-CDCP1 NPs, the CEUS imaging of agent gradually enhanced, and enhanced imaging associated with the length of observing time. Furthermore, it was testified that anti-CDCP1 assisted the agent to target cells expressing CDCP1, which demonstrated the active targeting of anti-CDCP1 NPs in vitro . CONCLUSION: All in all, the feasibility of using targeted anti-CDCP1 NPs to enhance ultrasound imaging has been demonstrated in vitro , which laid a solid foundation for molecular US imaging in vivo , and anti-CDCP1 NPs might have a great clinical application prospect. Show more
Keywords: Targeted nanoparticle, contrast agent, prostate cancer
DOI: 10.3233/CH-200900
Citation: Clinical Hemorheology and Microcirculation, vol. 80, no. 1, pp. 25-35, 2022
Authors: Luo, Zhi-Yan | Hong, Yu-Rong | Yan, Cao-Xin | Wang, Yong | Ye, Qin | Huang, Pintong
Article Type: Research Article
Abstract: OBJECTIVES: The aim of this study was to find the optimal parameters and cutoffs to differentiate metastatic lymph nodes (LNs) from benign LNs in the patients with papillary thyroid carcinoma (PTC) on the quantitative contrast-enhanced ultrasound (CEUS) features. METHODS: A total of 134 LNs in 105 patients with PTCs were retrospectively enrolled. All LNs were evaluated by conventional ultrasound (US) and CEUS before biopsy or surgery. The diagnostic efficacy of CEUS parameters was analyzed. RESULTS: Univariate analysis indicated that metastatic LNs more often manifested centripetal or asynchronous perfusion, hyper-enhancement, heterogeneous enhancement, ring-enhancing margins, higher PI, …larger AUC, longer TTP and DT/2 than benign LNs at pre-operative CEUS (p < 0.001, for all). Multivariate analysis showed that centripetal or asynchronous perfusion (OR = 3.163; 95% CI, 1.721–5.812), hyper-enhancement(OR = 0.371; 95% CI, 0.150–0.917), DT/2 (OR = 7.408; 95% confidence interval CI, 1.496–36.673), and AUC (OR = 8.340; 95% CI, 2.677–25.984) were predictive for the presence of metastatic LNs. The sensitivity and accuracy of the quantitative CEUS were higher than qualitative CEUS (75% vs 55 % and 83.6% vs 76.1 %, respectively). CONCLUSIONS: Quantitative CEUS parameters can provide more information to distinguish metastatic from benign LNs in PTC patients; In particular, DT/2 and AUC have a higher sensitivity and accuracy in predicting the presence of metastatic LNs and reduce unnecessary sampling of benign LNs. Show more
Keywords: Contrast-enhanced ultrasound, lymph node metastasis, papillary thyroid carcinoma, ultrasound
DOI: 10.3233/CH-200909
Citation: Clinical Hemorheology and Microcirculation, vol. 80, no. 1, pp. 37-48, 2022
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]