Affiliations: Department of Radiology, Incheon St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Incheon, Korea | Department of Radiation oncology, Seoul St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul, Korea | Department of Surgery, Seoul St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul, Korea | Department of Radiology, Seoul St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul, Korea | Department of Radiology, St. Vincent Hospital, College of Medicine, The Catholic University of Korea, Suwon, Korea
Note: [] Corresponding author. E-mail: [email protected]
Abstract: We assessed the role of F-18 FDG PET/CT in evaluating isolated extra-axillary lymph node recurrences in postoperative breast cancer patients and its prognostic value on clinical outcome. We reviewed PET/CT scans of postoperative breast cancer patients performed at our institution between July 2003 and February 2012. We recorded PET/CT findings, clinicopathologic variables and treatment modalities. We analyzed metabolic parameters from PET/CT and clinicopathologic variables with respect to progression free survival (PFS). A total of 3561 PET/CT scans were performed in 1906 postoperative breast cancer patients with a median interval of 43 month from curative surgery. Fifty seven patients (2.99%) demonstrated isolated extra-axillary nodal recurrences (n=85) on PET/CT (internal mammary node recurrences in 28, supraclavicular 24, infraclavicular 4, interpectoral 8, cervical 12, and mediastinal 9).The median SUVmax was 7.8 (range, 1.8~19.0), and the median node size was 15 mm (range, 6~38 mm). All recurrences were nonpalpable. Based on PET/CT findings, 53 out of 57 patients with extra-axillary node recurrences underwent subsequent chemotherapy/radiation therapy. The estimated 3-year PFS rate was 48.6%. Cutoff points of SUVmax 2.7 and size 14 mm were the best discriminative values for predicting clinical outcome. SUVmax and size of extra-axillary nodal recurrences were significantly correlated to PFS on univariate and multivariate analyses (p<0.001 and p=0.019, respectively).
Keywords: Breast cancer, extra-axillary lymph node, recurrence, PET/CT, prognosis
DOI: 10.3233/BME-130918
Journal: Bio-Medical Materials and Engineering, vol. 24, no. 1, pp. 1173-1184, 2014
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]