Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Issue title: Frontiers in Biomedical Engineering and Biotechnology – Proceedings of the 2nd International Conference on Biomedical Engineering and Biotechnology, 11–13 October 2013, Wuhan, China
Article type: Research Article
Authors: Liang, Fuyou;
Affiliations: SJTU-CU International Cooperative Research Center, School of Naval Architecture, Ocean & Civil Engineering, Shanghai Jiao Tong University, 800 Dongchuan Road, Shanghai, China
Note: [] Corresponding author. E-mail: [email protected]
Abstract: Central aortic pressures are better predictors of cardiovascular events than peripheral pressures. However, central aortic blood pressures cannot be measured noninvasively; for this reason, estimating aortic pressures from noninvasive measurements of peripheral pressures has been the subject of numerous studies. In the present study, a novel method was proposed to noninvasively estimate aortic pressures from the oscillometric wave of a suprasystolic brachial cuff. The errors of estimation were evaluated in relation to various cardiovascular properties using an integrated cardiovascular-cuff model. Obtained results demonstrated that the estimation errors are affected mainly by aortic stiffness. The estimation errors for aortic systolic pressure, diastolic pressure, pulse pressure and wave shape under the assumed cardiovascular conditions were 5.84±1.58 mmHg, −0.28±0.41 mmHg, 6.12±1.42 mmHg and 1.72±0.57 mmHg, respectively, all of which fell within the error ranges established by existing devices. Since the method is easy to be automated and bases the estimation fully on patient-specific information, its clinical application is promising, although further clinical studies are awaited to validate the method in vivo.
Keywords: Central aortic pressure, suprasystolic brachial cuff, oscillometric signal, wave separation, wave reconstruction
DOI: 10.3233/BME-130903
Journal: Bio-Medical Materials and Engineering, vol. 24, no. 1, pp. 1053-1062, 2014
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]