Issue title: Frontiers in Biomedical Engineering and Biotechnology – Proceedings of the 2nd International Conference on Biomedical Engineering and Biotechnology, 11–13 October 2013, Wuhan, China
Article type: Research Article
Authors: Yu, Chang Ho | Ohta, Makoto | Kwon, Tae Kyu; ;
Affiliations: Division of Biomedical Engineering, Chonbuk National University, Deokjin-Dong 1-Ga, Jeonju, Jeonbuk 561-756, South Korea | Institute of Fluid Science, Tohoku University, 2-1-1 Katahira, Aoba-ku, Sendai, Miyagi 980-8577, Japan | Bioengineering Research Center for the Aged, Chonbuk National University, Jeonju, Jeonbuk 561-756, South Korea
Note: [] Corresponding author. E-mail: [email protected]
Abstract: In this paper, we investigated several parameters with effect on the compressive force to assess the mechanical properties of interventional device. We find several parameters are highly influential and others are not. In our evaluation system, we prepared a box-shaped PVA-H and silicone with realistic geometry and carried out the measurement and evaluation of the pushability by using load cell machine. The parameters of velocity, position of device in the system do not affect the compressive force, whereas the length of catheter from the tip to fixed point is one of the most influential parameters for the force. Several behaviors such as passing through the curve or slip and stop can be observed and defined using this system. The balance of the bending force and the pushing force may make the tip with behavior of slip and stop or passing thorough the curve. The investigation of the evaluation system confirmed that high reproducibility with short error bar is indicated. The observation with movie record is also an advantage of our system because the high transparency of materials with silicone and PVA-H can check the inside of artery.
Keywords: Blood vessel biomodel, PVA-H, pushability, interventional device
DOI: 10.3233/BME-130891
Journal: Bio-Medical Materials and Engineering, vol. 24, no. 1, pp. 961-968, 2014
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]