Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Issue title: Frontiers in Biomedical Engineering and Biotechnology – Proceedings of the 2nd International Conference on Biomedical Engineering and Biotechnology, 11–13 October 2013, Wuhan, China
Article type: Research Article
Authors: Choi, Ahnryul | Rim, Yonghoon | Mun, Jeffrey S. | Kim, Hyunggun;
Affiliations: Division of Cardiovascular Medicine, Department of Internal Medicine, The University of Texas Health Science Center at Houston, 6431 Fannin St. MSB 1.246, Houston, Texas, USA | Seoul International School, Bokjeong-dong, Sujeong-gu, Seongnam, Gyeonggi-do, South Korea
Note: [] Corresponding author. E-mail: [email protected]
Abstract: Alterations of normal mitral valve (MV) function lead to mitral insufficiency, i.e., mitral regurgitation (MR). Mitral repair is the most popular and most efficient surgical intervention for MR treatment. An annuloplasty ring is implanted following complex reconstructive MV repairs to prevent potential reoccurrence of MR. We have developed a novel finite element (FE)-based simulation protocol to perform patient-specific virtual ring annuloplasty following the standard clinical guideline procedure. A virtual MV was created using 3D echocardiographic data in a patient with mitral annular dilation. Proper type and size of the ring were determined in consideration of the MV apparatus geometry. The ring was positioned over the patient MV model and annuloplasty was simulated. Dynamic simulation of MV function across the complete cardiac cycle was performed. Virtual patient-specific annuloplasty simulation well demonstrated morphologic information of the MV apparatus before and after ring implantation. Dynamic simulation of MV function following ring annuloplasty demonstrated markedly reduced stress distribution across the MV leaflets and annulus as well as restored leaflet coaptation compared to pre-annuloplasty. This novel FE-based patient-specific MV repair simulation technique provides quantitative information of functional improvement following ring annuloplasty. Virtual MV repair strategy may effectively evaluate and predict interventional treatment for MV pathology.
Keywords: Mitral valve, annuloplasty, mitral repair, patient-specific, finite element
DOI: 10.3233/BME-130816
Journal: Bio-Medical Materials and Engineering, vol. 24, no. 1, pp. 341-347, 2014
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]