Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Issue title: Frontiers in Biomedical Engineering and Biotechnology – Proceedings of the 2nd International Conference on Biomedical Engineering and Biotechnology, 11–13 October 2013, Wuhan, China
Article type: Research Article
Authors: Yu, Hui; | Zhang, Shu-xu | Wang, Rui-hao | Zhang, Guo-qian | Tan, Jian-ming
Affiliations: Department of Radiotherapy, the Affiliated Tumor Hospital of Guangzhou Medical University, Guangzhou 510095, P.R. China
Note: [] Corresponding author. E-mail: [email protected].
Abstract: Calculating an accurate cumulative dose through individual phases for four-dimensional computed tomography (4DCT) images from the lung is time-consuming. Although the dose distribution of different phases is similar, copying the dose distribution of one phase directly to another phase would yield a dosimetric error of approximately 4% without further optimization. To reduce the dosimetric error, three-dimensional B-spline elastic deformable image registration (DIR) was used to quickly obtain a relatively accurate cumulative dose of 4DCT images acquired from ten lung cancer patients. The dose distribution of the end-expiration phase was mapped to the end-inspiration phase using DIR. The mapped dose in the end-inspiration phase was then compared with the directly copied dose by analysis (3cm/3%) and the t-test. The results showed that optimization using DIR was significantly better in the average pass rate (by 0.6–4.7%). Our results indicate it is feasible to map the dose distribution of 4DCT images in lung with DIR, and that the motion amplitude of individual respiratory and different DIR algorithms affect the differences between the mapped and actual dose.
Keywords: 4DCT, deformable image registration, dose distribution, γ analysis
DOI: 10.3233/BME-130794
Journal: Bio-Medical Materials and Engineering, vol. 24, no. 1, pp. 145-153, 2014
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]