Affiliations: Department of Biomedical Engineering, College of Engineering, The University of Iowa, Iowa City, IA 52242, USA
Abstract: The hoop and axial strains present due to loading after femoral stem implantation in canine femurs, implanted with and without a wire coil surrounding the distal tip were investigated. One stem served as the control without wire coil while the other was experimental reinforced with a wire coil. Both stems were implanted by identical methods. Ideally, the wire coil should serve to reduce the hoop and axial strains present in the distal tip of the arthroplasty. The strains were measured using 90° rosette strain gages. Though the coil's position was altered slightly during implantation usable results were still obtained. At a maximum load of 44.5 N there were 32 and 19% reduction in the hoop and axial strains for the reinforced stem and the control, respectively. This experiment presents a striking difference between the control and reinforced hip arthroplasties. Equally important is that this study confirms the trends in hoop and axial strain behavior demonstrated in other works utilizing a wire coil reinforcement scheme. The simple method of applying a continuous wire coil may help to reduce the loosening of femoral stem of total hip arthroplasty by reducing strains at the tip of the stem due to the strengthening of the cement mantle.
DOI: 10.3233/BME-1997-7403
Journal: Bio-Medical Materials and Engineering, vol. 7, no. 4, pp. 245-251, 1997
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]