Article type: Research Article
Authors: Lewis, Gladius; | Shaw, Kevin M.
Affiliations: Department of Mechanical Engineering, The University of Memphis, Campus Box 526576, Memphis, TN 38152-6576, USA | Yale Hoists, Forrest City, AR 72345, USA
Note: [] Corresponding author.
Abstract: Uniaxial quasi-static tensile stress, σ, versus strain, ε, data were obtained from 29 cadaveric Achilles tendons (donor ages: 36 to 100 years), at a strain rate of either 10 or 100%/s. These results were then used in modeling the elastic component of the tensile deformational behavior of this tissue. Two approaches were taken. In the first, it was shown that the following constitutive relation provided an excellent fit to the elastic section of the σ−ε curve, σ=Cεexp[Dε+Fε2], with C, D and F being material constants, whose values for the present dataset were found to be C = 2.00 ± 0.99, D = 0.089 ± 0.087 and F = −0.0047 ± 0.0095. The values of these coefficients were not statistically significantly affected by either donor age or test strain rate. In the second approach, the value of the modulus of elasticity of a filamentary polymer matrix composite material was computed as a function of various combinations of values of the modulus of elasticity of the fiber, the modulus of elasticity of the matrix, and angle of orientation of the principal material axes with respect to the reference coordinate axes (θ) for a fiber volume fraction of 0.6 and a material Poisson's ratio of 0.4. By comparing these results with the experimentally-obtained values of the tangent modulus of elasticity of the tendons (defined as the slope of the linear section of the post-toe zone in the σ−ε plot), and assuming that the tendon may be idealized as a filamentary polymer matrix composite material, the suggestion is made that the winding angle of the fibers (collagen fibrils) in the tendon (taken to be equal to θ) is about 6°.
Keywords: Achilles tendon, constitutive relation, composite material
DOI: 10.3233/BME-1997-7402
Journal: Bio-Medical Materials and Engineering, vol. 7, no. 4, pp. 231-244, 1997
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]