Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Kwon, S.Y. | Kim, Y.S. | Woo, Y.K. | Kim, S.S. | Park, J.B.
Affiliations: Department of Orthopedic Surgery, Catholic University Medical College, 62 Yeoido, Yeoung deongpo-ku, Seoul, Korea | Department of Biomaterials, Korea Research Institute of Chemical Technology, DaeJeon, Korea | Department of Biomedical Engineering, College of Engineering, The University of Iowa, Iowa City, Iowa 52242, USA
Abstract: Hydroxyapatite (HA) particle impregnated polymethylmethacrylate (PMMA) bone cement was fabricated in order to induce bony tissue ingrowth into the pores left behind by resorption of the HA. The amount of HA was 0%, 10%, and 30% by weight. After mixing the HA with bone cement it was cast in a 4 mm inside diameter glass tube (10 mm long). Each specimen was cut into half and used for in vitro and in vivo experiment. Diametral tensile and flexural bend tests were made to evaluate its mechanical properties. SEM (scanning electron microscope) and ESCA (electron spectroscopy for chemical analysis) were used to evaluate the surface characteristics of the specimen. Push-out test and histology studies were made after implanting the specimens for six weeks in the distal portion of rabbit femur. The mechanical test results showed significant decrease of the flexural and diametral tensile strength linear with the increased amount of HA (p < 0.05). The SEM and ESCA analyses showed no definite exposure of HA particles on the surface of the specimens due to the covering by PMMA. The interfacial shear strength of the implanted specimens showed significant increases in the 30% HA specimens compared with the 0% ones but the 10% specimens did not show any difference. Histological observation showed little HA particle apposition to new bone in 10% specimens but more in the 30% ones. In conclusion, this study showed the decreased mechanical properties both by increasing the amount of HA particles and with the bone particles impregnated bone cement. In vivo study showed much lower interfacial shear strength due to implant site compared to other studies but the 30% HA specimens showed statistically significant increase in the push-out strength after implanting into the distal end of rabbit femora.
Keywords: Bone cement, bone ingrowth, hydroxyapatite, rabbit femur
DOI: 10.3233/BME-1997-7205
Journal: Bio-Medical Materials and Engineering, vol. 7, no. 2, pp. 129-140, 1997
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]