Article type: Research Article
Authors: Asano, Takuji; | Kinoshita, Yoshihiko | Kobayashi, Masaki | Nakao, Michiharu | Kanazawa, Hidetoshi | Hara, Yasuko | Furuse, Motomasa | Kuroiwa, Toshihiko
Affiliations: Nikkiso Co., Tokyo, Japan | Department of Neurosurgery, Osaka Medical College, Osaka, Japan
Note: [] Address for correspondence: Takuji Asano, Nikkiso Co., Ltd., Ebisu, Shibuya-ku, 150-8677, Tokyo, Japan. Tel.: +81 3 3443 3827; Fax: +81 3 3443 3263; E-mail: [email protected].
Abstract: The clinical treatments with blood purification therapy is most suitable in which a blood compatible adsorbent is employed. In the present study, two kinds of adsorber with different filling ratio (% rate with a bulk volume in the column volume (v)) with 83% (PAB-83) and 100% (PAB-100) were prepared, respectively. The adsorbent (PAB – Poly Arylate Beads), which was filled up in the column, was prepared with the phase-inversion method. Usually the major problems of blood purification therapy are blood clotting and the residual blood in the column during/after therapy process. The therapy should be interrupted when the internal pressure of the column dramatically go up by such problems. We concluded that PAB does not affect the blood clotting formation in terms of endogenous clotting parameters, i.e., activated partial thromboplastin time (APTT), prothrombin time (PT) and the amount of fibrinogen (Fib). They lead to not dramatically decreasing of the essential protein. These adsorbers might be available to use as the adsorptive device for the blood purification therapy.
Keywords: Blood compatibility, filling ratio, blood purification, adsorbent
DOI: 10.3233/BME-2010-0614
Journal: Bio-Medical Materials and Engineering, vol. 20, no. 1, pp. 47-54, 2010
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]