Abstract: Diamond-like carbon (DLC) films were deposited on stainless steel (SUS), titanium (Ti) and nickel titanium (Ni–Ti) substrates using a radiofrequency plasma chemical vapour deposition method. Prior to DLC coating, the substrates were exposed to O2 and N2 plasma to enhance the adhesion strength of the DLC film to the substrate. After the plasma pre-treatment, the chemical composition and the wettability of the substrate surface was investigated by X-ray photoelectron spectroscopy (XPS) and water contact angle measurement, respectively. A pull-out test and a ball-on-disc test were carried out to evaluate the adhesion strength and the wear properties of the DLC-coated substrates. The XPS results showed that the N2 and O2 plasma pre-treatment produced nitride and oxide on the substrate surfaces, such as TiO2, TiO, Fe2O3, CrN and TiNO. In the pull-out test, the adhesion strengths of the DLC film to the SUS, Ti and Ni–Ti substrates were improved with the plasma pre-treatment. In the ball-on-disc test, the DLC coated SUS, Ti and Ni–Ti substrates without the plasma pre-treatment showed severe film failure following the test. The DLC coated SUS and Ni–Ti substrates with the N2 plasma pre-treatment showed good wear resistance, compared with that with the O2 plasma pre-treatment.
Keywords: Diamond-like carbon, SUS, Ti, Ni–Ti, plasma CVD, plasma pre-treatment, adhesion, wear property
DOI: 10.3233/BME-2010-0612
Journal: Bio-Medical Materials and Engineering, vol. 20, no. 1, pp. 21-35, 2010
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]