Authors: Ohashi, Minako; | Tomita, Naohide; | Ikada, Yoshito | Ikeuchi, Ken | Motoike, Toshio
Affiliations: Research Center for Biomedical Engineering, Kyoto University, 53 Kawahara-cho, Shogoin, Sakyo-ku Kyoto 606, Japan, Tel.: 075 751 4840; Fax: 075 751 4144 | Hitachi Building Machinery, 4-8-17 Nishitenma Kita-ku, Osaka 530, Japan
Note: [] Author.
Note: [] Responder.
Abstract: Ultra high molecular weight polyethylene (UHMWPE) has been used in artificial joints for a few decades, and wear of UHMWPE has been one of the main problems. Though many other materials have been tested over the years, the best clinical results are still achieved with UHMWPE. This makes the study of UHMWPE, especially in relation to artificial joints, very important. Frequently, more severe wear can be observed in artificial knee joints than in artificial hip joints especially when the flaking-like wear occurs. This flaking-like wear can lead to significant destruction of the artificial knee joint. Macroscopically, artificial knee joints have combinational movements of rolling and sliding in order to simulate the motion of the normal knee joint. The components of motion are separated to make study easier. Fatigue tests of UHMWPE under the rolling contact condition were performed in this study. Three ceramic spheres were rolled over the UHMWPE specimen using 37°C distilled water as a lubricant. The UHMWPE specimen was observed by the scanning acoustic tomography, microscopy, and SEM. Some subsurface defects could be observed by SAT even before experiments. Although the apparent wear is not observed on the surface, there was an increase in the number of observable subsurface cracks in the UHMWPE specimen. This shows that cracks occur under the surface after a 107 rolling contact loading, which is very close to the cyclic loading and unloading with very little friction compared to the sliding contact.
Keywords: Fatigue, wear, UHMWPE, SAT, artificial knee joint
DOI: 10.3233/BME-1996-6605
Journal: Bio-Medical Materials and Engineering, vol. 6, no. 6, pp. 441-451, 1996
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]