Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Hedia, H.S. | Barton, D.C.; | Fisher, J. | Elmidany, T.T.
Affiliations: Department of Mechanical Engineering, Leeds University, Leeds, LS2 9JT, UK | Department of Production Engineering, Faculty of Engineering, Mansoura University, Mansoura, Egypt
Note: [] Corresponding author.
Abstract: The load transferred through the hip joint is one of the major forces occurring in the human body. After the replacement of this joint in THR arthoplasty, the load is transferred through the implant to the femoral bone. Loosening of the fixation of the implant and the fatigue failure of prosthetic stems create problems for both patient and surgeon. Both problems can be reduced by the use of Finite Element (FE) analysis to predict stresses and fatigue lifes but the results are sensitive to assumptions regarding the loading conditions and the idealisation of the components. Consequently the stress distributions and resulting fatigue notch factors in the human femur with an endoprosthesis have been determined for different assumptions regarding the form of the idealisation, the load conditions, and the interface conditions. The FE results show that a realistic loading condition without a tension banding force always produces the highest fatigue notch factor and von Mises stresses. An equivalent 2D plane stress model obtained by varying the thickness is likely to give more realistic stresses because it predicts more realistic strains than other 2D approximations. The full bonded interface is a satisfactory. approximation for the real interface conditions because it predicts stress distributions of the correct form without excessive stress concentration.
Keywords: Von Mises stress, fatigue notch factor, loading conditions, interface conditions
DOI: 10.3233/BME-1996-6301
Journal: Bio-Medical Materials and Engineering, vol. 6, no. 3, pp. 135-152, 1996
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]