Article type: Research Article
Authors: Babizhayev, Mark A.; ; | Chumayevskii, Nikolai A.
Affiliations: Moscow Helmholtz Research Institute of Eye Diseases, Moscow, Russia | Kumakov Institute of General and Inorganic Chemistry, Moscow, Russia
Note: [] This work is a part of the Research Programme established by the Chemobyl Workers Goodwill Union and is supported by its Moscow Division.
Note: [] Reprint requests and correspondence should be addressed to Dr. Mark A. Babizhayev, Moscow Helmholtz Research Institute of Eye Diseases, 14/19 Sadovaya-Chemogryazskaya, Moscow 103064, Russia.
Abstract: Intraocular lenses (IOL) made of polymethyl methacrylate (PMMA) lack an important yellowish pigment useful as a filter in the visual process and in the protection of the retina from short wavelength light. It was found that the PMMA used for IOL manufacturing can be tinted by dry exposure to mercury near-UV emitting lamp (emission maximum, 365 nm, light bandwidth ± 140 nm; irradiance of 50–100 W/sq m as measured at the PMMA surface; time of exposure 70–100 h, room temperature). The UV irradiated samples were stored in the atmosphere of N2 under the heating-protected and clean conditions. The IOL sample holder allowed to remove IOL loops and their fixation areas from the zone of the passing light. The absorptive properties of IOLs treated with UV light were similar to those of young human lenses. Raman vibration and fluorescence spectral analyses of IOLs have shown that the yellow colour and its intensity in the irradiated samples depends on the presence of conjugated C=C and C=O groups (π−π conjugation) in the chemical composition of PMMA. When the PMMA samples were exposed for 70 h to a high level of UV radiation (50–100 W/sq m) no damage was seen with scanning electron microscopy at both side surfaces of the IOLs. The PMMA water exhaustive extracts made by 70 h of UV radiation exposure did not show any cytological damage when injected into the cell cultures of fibroblasts. The threshold for optical breakdown in PMMA was detected by 100 h of UV radiation at the level of exposure equivalent to at least 20,000 times levels for expected ambient UV exposure to PMMA within the eye. A rigorous quality index defmed as the ratio of the line C = C/C = O stretching mode intensities was introduced for the UV-absorbing PMMA photostability. The findings suggest an applicability of the photochemical tinting and further research to test the efficacy and safety of UV-absorbing chromophore induction in the PMMA IOLs.
Keywords: intraocular lenses, polymethyl methacrylate, ultraviolet irradiation, Raman and fluorescence spectroscopy, surface area effects, biocompatibility and cytotoxicity, ultraviolet-absorbing chromophores
DOI: 10.3233/BME-1994-4101
Journal: Bio-Medical Materials and Engineering, vol. 4, no. 1, pp. 1-16, 1994
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]