Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Oshida, Yoshiki | Hashem, Azza
Affiliations: Department of Restorative Dentistry, Indiana University School of Dentistry, 1121 West Michigan Street, Indianapolis, IN 46202-5186 USA
Abstract: The bonding strength of porcelains to metals depends on the oxide layer between the porcelain and the metal. Oxidation of a metal surface increases the bonding strength, whereas excessive oxidation decreases it. Titanium and its alloys are gaining acceptance for dental use since they exhibit excellent biocompatibility, corrosion resistance, low specific gravity, good mechanical properties, and low cost. However, titanium suffers from its violent reactivity with oxygen at high temperatures that yields an excessive thick layer of TiO2, and this presents difficulties with porcelain bonding. The present study deals with the oxidation kinetics of titanium simulated to porcelain firing and evaluating surface nitridation of titanium as a process of controlling the oxidation behavior of titanium. Nitrided samples with the Arc Ion Plating PVD process and un-nitrided control commercially pure titanium (CPT, Grade 1) were subjected to oxidation simulating firing of Procera porcelain with 550°, 700°, and 800°C firing temperatures for 10 min in both 1 and 0.1 atmospheric air. Weight difference before and after oxidation was calculated and the parabolic rate constant, Kp (mg2/cm4/s), was plotted against inverse absolute temperature. Surface layers of the samples were subjected to x-ray and electron diffraction techniques for phase identifications. Results revealed that both nitrided and un-nitrided samples obey a parabolic rate law with activation energy of 50 kcal/mol. In addition this study shows that nitrided CPT had a Kp about 5 times lower than the un-nitrided CPT and hence the former needs about 2.24 times longer oxidation time to show the same degree of oxidation. Phase identification resulted in confirming the presence of TiO2 as the oxide film in both groups but with 1 – 2 μm thickness for the un-nitrided CPT and 0.3 – 0.5 μm thickness for the nitrided samples. Therefore it can be concluded that nitridation of titanium surface can be effective in controlling the surface oxide thickness that might ensure satisfactory bonding with porcelain.
Keywords: pure titanium, metal ceramic system, nitrided titanium, oxidation, x-ray, transmission electron diffraction
DOI: 10.3233/BME-1993-3402
Journal: Bio-Medical Materials and Engineering, vol. 3, no. 4, pp. 185-198, 1993
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]