Article type: Research Article
Authors: Fu, Weihua | Dai, Jianrong | Hu, Yimin
Affiliations: Department of Radiation Oncology, Cancer Institute (Hospital), Peking Union Medical College, Chinese Academy of Medical Sciences, Beijing 100021, China
Note: [] Corresponding author: Yimin Hu, Department of Radiation Oncology, Cancer Institute (Hospital), PUMC, CAMS, PO Box 2258, Beijing 100021, P.R. China. Tel.: +86 10 67737011; Fax: +86 10 67737011; E‐mail: [email protected].
Abstract: Using higher energy photons can obtain better target dose uniformity and skin sparing for treating deep lesions, but the effect of lacking lateral scattering in the low‐density lung may degrade the target coverage. To analyze the influence of lateral electronic disequilibrium on the radiation treatment planning for lung cancer, three dimension conformal treatment (3D‐CRT) plans of using 6 MV and 18 MV X‐ray respectively for a lung cancer case have been worked out by using pencil beam algorithm and collapsed cone algorithm provided by Helax‐TMS treatment planning system for the same radiation field arrangement for both energies. Dose volume histogram (DVH) in target and organs at risk (OARs) are used for comparison of different plans. The study shows that using pencil beam algorithm, the target DVH are similar for 6 MV and 18 MV plan. However, using collapsed cone algorithm that can make account of lateral electron scattering, the target is underdosed. The change is even more pronounced for 18 MV plan. The doses for lung and spinal cord are similar for these two energies and two algorithms. Therefore, for lung cancer, dose calculation algorithm should have the ability of handling accurately the effect of the tissue density heterogeneity. It is better to use the lower‐energy photons (6 MV) than to use the higher‐energy photons (18 MV).
Keywords: Lateral electronic disequilibrium, pencil beam algorithm, collapsed cone algorithm
Journal: Bio-Medical Materials and Engineering, vol. 14, no. 1, pp. 123-126, 2004
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]