Article type: Research Article
Authors: Ozeki, K.; | Yuhta, T. | Aoki, H. | Fukui, Y.
Affiliations: Applied Systems Engineering, Graduate school of Science and Engineering, Tokyo Denki University, Ishizaka, Hatoyama, Hiki, Saitama, 350‐0394, Japan | Frontier Research and Development Center, Tokyo Denki University, Ishizaka, Hatoyama, Hiki, Saitama, 350‐0394, Japan
Note: [] Corresponding author. Tel.: +81‐(0)49‐296‐2911(3752); Fax: +81‐(0)49‐296‐2925; E‐mail: [email protected].
Abstract: To alleviate the effects of Ni allergy from NiTi alloy implants, hydroxyapatite (Ca10(PO4)6(OH)2; HA), alumina (Al2O3), or titanium (Ti) was coated onto NiTi alloy plates to form 1‐μm thick films using radio frequency magnetron sputtering. The coatings on the plates were characterized using XRD. After the plates had been immersed in physiological saline for periods of one, four, or eight weeks, the concentration of Ni ions released in each solution was detected using a microwave induced plasma mass spectrometer. After eight weeks, the concentration of Ni ions released from the non‐coated, the Ti‐coated, the HA‐coated, and the alumina‐coated plates were 238, 19.7, 183, and 106 ppb, respectively. The bonding strength of the Ti film, the HA film, and the alumina film to the NiTi substrate were 3.8±1.2, 2.6±0.7, and 3.1±1.2 MPa, respectively. The non‐coated, the HA‐coated, the alumina‐coated, and the Ti‐coated plates were implanted into the femurs of a dog for four weeks for histological observation. In case of the non‐coated plates, connective tissue more than 300 μm thick was observed, whereas for the coated plates the thickness of the connective tissue was around 100 μm.
Keywords: NiTi alloy, Ni allergy, sputtering, titanium, hydroxyapatite, alumina
Journal: Bio-Medical Materials and Engineering, vol. 13, no. 3, pp. 271-279, 2003
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]