Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Cheng, Cheng‐Kung | Chen, Chen‐Sheng; | Liu, Chien‐Lin
Affiliations: Orthopaedic Biomechanics Laboratory, Institute of Biomedical Engineering, National Yang‐Ming University, Taipei, Taiwan | Department of Orthopaedic Surgery, Veteran General Hospital‐Taipei, Taipei, Taiwan
Note: [] Corresponding author: Cheng‐Kung Cheng, Ph.D., Institute of Biomedical Engineering, National Yang‐Ming University, 155 Sec. 2, Li‐Nung St., Taipei, Taiwan. Tel.: 886 2 28267020; Fax: 886 2 28202519; E‐mail: [email protected].
Abstract: The anterior lumbar interbody fusion is the common procedure in the management of the degenerated disc in the lumbar spine, but the biomechanical behavior of the fused segment would be changed because of the implantation of bone graft at the different locations. To investigate the biomechanical alteration, the study applied the finite element model to undergo the stress analysis. A three‐dimensional finite element model of the lumbar spine was established, and modified to the three fusion models consisted of the bone graft at the anterior site, the middle site and the posterior site, respectively. The 12 N m flexion and the 10 N m torsion with pre‐load 150 N were imposed on the L1 vertebral body. The results of the finite element model indicated that placing bone graft at anterior site could effectively resist flexion moment, and decreased the tensile force of the posterior ligaments about 15% above. Placing bone graft at posterior site could resist torsional moment, and also led to none of contact force of the facet joint in the fused segment. However, wherever the bone grafts were placed, stress slightly increased on the disc adjacent to interbody fusion about 5% below.
Keywords: Finite element analysis, lumbar spine, bone graft
Journal: Bio-Medical Materials and Engineering, vol. 12, no. 4, pp. 367-374, 2002
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]