Affiliations: Biorthex Inc., R&D ‐ Biomaterials Department, 9001 Boul. L'Acadie, suite 802, Montreal (QC) H4N 3H5, Canada | National Research Council Canada (NRC), Industrial Materials Institute (IMI), 75 Boul. de Mortagne, Boucherville (QC) J4B 6Y4, Canada | Hôpital Ste‐Justine, Centre de Recherche Pédiatrique, 3175 ch. Côte Ste‐Catherine, Montreal (QC) H3T 1C5, Canada
Note: [] Corresponding author: Michel Assad, Ph.D. Tel.: 1 514 382 4800, ext.: 203; Fax: 1 514 382 4048; E‐mail: [email protected].
Abstract: Porous titanium–nickel (PTN) represents a new biomaterial with orthopedic applications as a long‐term implant. Because of its nickel content, PTN was tested for its potential to stimulate sensitization, irritation, and systemic toxicity reactions after semi‐physiological extraction. In order to do so, an in vivo biocompatibility evaluation was performed following three ISO‐standardized methods using accepted animal models for immunity testing: the classical skin sensitization assay (Buehler patch test) in guinea pigs, the rabbit intracutaneous test, and the systemic injection test in mice. The Buehler patch test in guinea pigs revealed no significant change in skin reactions such as erythema or swelling between the induction and the challenge period. In the rabbit intracutaneous irritation test, no irritation or sensitization reactions were observed in saline‐extracted PTN samples. Negligible to slight irritation was observed at some of the sites involving PTN samples extracted in cottonseed oil, however the resulting primary irritation index was similar to the one elicited by the blank solution itself. Finally, no toxic symptoms were observed with any of the mice injected with porous titanium–nickel extracts during the acute systemic toxicity test. Based on the above results, porous titanium–nickel is considered to be a non‐sensitizing, non‐irritant, and non‐toxic biomaterial for medical applications.
Keywords: Porous, titanium–nickel, biocompatibility, sensitization testing, irritation testing
Journal: Bio-Medical Materials and Engineering, vol. 12, no. 4, pp. 339-346, 2002
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]