Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Morita, Yusuke | Tomita, Naohide; | Aoki, Hideyuki | Wakitani, Shigeyuki | Tamada, Yasushi | Suguro, Toru | Ikeuchi, Ken
Affiliations: Institute for Frontier Medical Sciences, Kyoto University, 53 Kawahara‐cho, Shogoin, Sakyo‐ku, Kyoto 606‐8507, Japan | Department of Orthopaedic Surgery, School of Medicine, Toho University, 6‐11‐1 Omorinishi, Ota‐ku, Tokyo 143‐8541, Japan | Department of Orthopaedic Surgery, Osaka‐Minami National Hospital, 2‐1 Kidohigashimati, Kawachinagano‐city, Osaka 586‐8521, Japan | National Institute of Sericultural and Entomological Science, 1‐2 Owashi, Tsukuba‐city, Ibaragi 305‐8634, Japan
Note: [] Corresponding author: Naohide Tomita, Institute for Frontier Medical Sciences, Kyoto University, 53 Kawahara‐cho, Shogoin, Sakyo‐ku, Kyoto 606‐8507, Japan. Tel. & Fax: +81 75 751 4109; E‐mail: [email protected]‐u.ac.jp.
Abstract: The mechanical properties of regenerated cartilage tissue were measured to evaluate changes in their visco‐elastic properties during cultivation. An indentation test and dynamic visco‐elasticity measurements were carried out on cartilage tissue cultured with rabbit chondrocytes that had been inoculated into the fibroin sponge. A 1.5‐mm‐diameter porous indentor was used for the indentation test, in which time‐dependent strain curves were derived from measurements taken under several loading conditions. Dynamic visco‐elasticity measurements were performed under compressive loading to evaluate the load‐bearing function of the articular cartilage. Although the amount of permanent deformation was not influenced by the duration of cartilage regeneration, the amount of creep deformation increased with longer cultivation. The E′ value of the regenerated cartilage increased and the peak value of tan δ and the frequency at the peak became lower with longer cultivation. It is suggested that the changes in the time‐dependent strain curves and dynamic visco‐elastic properties of the regenerated cartilage were caused by maturation of the cultured cartilage tissue.
Keywords: Articular cartilage, regeneration, fibroin sponge, indentation test, dynamic visco‐elasticity measurement
Journal: Bio-Medical Materials and Engineering, vol. 12, no. 3, pp. 291-298, 2002
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]