Article type: Research Article
Authors: Alam, Khurshida; | Iqbal, Muhammadb | Umer, Jamalc | Amjad, Muhammadd | Al-Ghaithi, Ahmede
Affiliations: [a] Mechanical and Industrial Engineering Department, Sultan Qaboos University, Al-Khoud, Sultanate of Oman | [b] Creative Engineering and Management Services, Deans Centre, Peshawar, Pakistan | [c] Department of Mechanical Engineering, University of Engineering and Technology, Lahore, Pakistan | [d] Department of Mechanical Engineering, International Islamic University, Sector H-11, Islamabad, Pakistan | [e] Department of Surgery, Sohar Hospital, Sohar, Sultanate of Oman
Correspondence: [*] Corresponding author: Khurshid Alam, Mechanical and Industrial Engineering Department, Sultan Qaboos University, Al-Khoud, Sultanate of Oman. E-mail: [email protected]
Abstract: BACKGROUND:Drilling is a well-known mechanical operation performed for fixing fracture at required locations in bone. The process may produce mechanical and thermal alterations in the structure of the bone and surrounding tissues leading to irreversible damage known as osteonecrosis. OBJECTIVE:The main purpose of this study was to measure the level of biological damage in bone when a drill assisted by low and high levels of vibrations is penetrated into bone tissue. METHODS:Histopathology examination of sections of bones has been performed after drilling the bone using a range of vibrational frequency and rotational speed imposed on the drill with and without supply of saline for cooling. RESULTS:Cell damage in bone was caused by the combined effect of drill speed and frequency of vibrations. Histopathology examination revealed more damage to bone cells when a frequency higher than 20 kHz was used in the absence of cooling. Cooling the drilling region helped minimize cell damage more at a shallow depth of drilling compared to deep drilling in the cortex of cortical bone. The contribution of cooling in minimizing cell damage was higher with a lower drill speed and frequency compared to a higher drill speed and frequency. CONCLUSION:Vibrational drilling using a lower drill speed and frequency below 25 kHz in the presence of cooling was found to be favorable for safe and efficient drilling in bone.
Keywords: Bone, bone drilling, vibrational drilling, bone temperature, cell damage, bone histology
DOI: 10.3233/BME-201122
Journal: Bio-Medical Materials and Engineering, vol. 31, no. 5, pp. 269-277, 2020
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]