Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Mitoh, Ayumia; | Suebe, Yutob | Kashima, Tadashia | Koyabu, Etaroa | Sobu, Eijia | Okamoto, Eijic | Mitamura, Yoshinorid | Nishimura, Ikuyad
Affiliations: [a] National Institute of Technology, Tomakomai College, Tomakomai, Japan | [b] Tohoku University, Sendai, Japan | [c] Tokai University, Sapporo, Japan | [d] Hokkaido University, Sapporo, Japan
Correspondence: [*] Corresponding author: Ayumi Mitoh, National Institute of Technology, Tomakomai College, 443 Nishikioka, Tomakomai 059-1275, Japan. Tel.: +81 0144 67 8012; Fax: +81 0144 67 8020; E-mail: [email protected]
Abstract: BACKGROUND:Thrombus formation and hemolysis are important factors in developing blood pumps and mechanical heart valve prostheses. These phenomena are induced by flow properties. High shear stress induces platelet and red cell damage. Computational fluid dynamics (CFD) analysis calculates shear stress of fluid and particle pathlines of blood cells. OBJECTIVE:We studied blood cell damage in a blood pump by using CFD analysis and proposed a method for estimating blood damage. METHODS:We analyzed a pulsatile blood pump that was developed as a totally implantable left ventricular assist system at Tokai University. Shear stress on blood cells throughout pulsatile blood pumps were analyzed using CFD software. RESULTS:Based on the assumption that the effect of shear stress on platelets is accumulated along the trace, we proposed a method for estimating blood damage using the damage parameter D. Platelet damage parameter is calculated regardless of the division time 𝛥t which is dependent on the calculation time step. The results of the simulations are in good agreement with Giersiepen’s equation obtained from the experiments. CONCLUSION:The history of shear stress on a particle was calculated using CFD analysis. The new damage parameter D yields a value close to that of Giersiepen’s equation with small errors.
Keywords: Computational fluid dynamics (CFD), shear stress, thrombus formation, hemolysis, blood pump
DOI: 10.3233/BME-201088
Journal: Bio-Medical Materials and Engineering, vol. 31, no. 3, pp. 169-178, 2020
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]