Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Robau-Porrua, Amanda a; | Pérez-Rodríguez, Yoan b | Soris-Rodríguez, Laura M.a | Pérez-Acosta, Osmel b | González, Jesús E.c
Affiliations: [a] Department of Technology of Machinery Construction, Mechanical Engineering Faculty, Technological University of Havana José Antonio Echeverría, Cuba | [b] Autonomous University of Nuevo León, FIME, México | [c] Department of Ceramic and Metallic Biomaterials, Biomaterials Center, University of Havana, Cuba
Correspondence: [*] Corresponding author: Amanda Robau-Porrua, Department of Technology of Machinery Construction, Mechanical Engineering Faculty, Technological University of Havana José Antonio Echeverría, Calle 114 #11901/Ciclovía y Rotonda, Marianao, La Habana, CP 19390, Cuba. Tel.: 5372663846; E-mail: [email protected], Web: www.cujae.edu.cu/en/
Abstract: This study investigated the effect of three different parameters of a dental implant on stress and strain values in the peri-implant bone by finite element analysis. In this work, the effect of diameter, length and elastic modulus on the biomechanical behavior of a new dental implant was simulated using the finite element method. A three-dimensional model of a mandible segment corresponding to the premolar region and twelve dental implant models were obtained. Loads in three directions were distributed on the surface of the coronal area of the dental implants. The dental implant models were obtained in the FreeCAD 0.16 software and the simulations were made using the Abaqus/CAE software. In all cases, higher stress concentrations were obtained in the peri-implant cortical bone between 40.6 and 62.8 MPa, while the highest levels of strain were observed in the peri-implant trabecular bone between 0.002544 and 0.003873. In general, the highest von Mises equivalent stress values were observed in the peri-implant cortical bone. However, in this bone, both the maximum von Mises equivalent stress values and the von Mises strain are similar or inferior to those reported in different studies by finite element for other models of dental implants under immediate loading. Maximum von Mises strain values were observed in peri-implant trabecular bone. However, in this bone strains levels were obtained that maintain bone density or increase it. The effect of the three simulated variables (implant diameter, length, and elastic modulus) have a statistically significant influence on the von Mises equivalent stress and in von Mises strain values.
Keywords: Dental implant, elastic modulus, finite element method, strain, stress
DOI: 10.3233/BME-191073
Journal: Bio-Medical Materials and Engineering, vol. 30, no. 5-6, pp. 541-558, 2020
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]