Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Syaifudin, Achmada; | Ariatedja, Julendra B.a | Kaelani, Yusufa | Takeda, Ryob | Sasaki, Katsuhikob
Affiliations: [a] Department of Mechanical Engineering, Faculty of Industrial Technology, Institut Teknologi Sepuluh Nopember, Surabaya, Indonesia | [b] Division of Human Mechanical Systems and Design, Faculty of Engineering, Hokkaido University, Sapporo, Japan
Correspondence: [*] Corresponding author: Achmad Syaifudin, Ph.D., Department of Mechanical Engineering, Faculty of Industrial Technology, Institut Teknologi Sepuluh Nopember, Surabaya, Indonesia. E-mail: [email protected]
Abstract: The utilization of Asymmetric stent for recovering atherosclerotic diseases, particularly non-symmetric obstruction, is a quite challenging breakthrough treatment. In terms of eccentric plaque, the non-uniform stiffness of arterial layer causes the increasingly complex issues of vulnerability. This study investigated the vulnerability of the interaction between the Asymmetric stent and the surrounding arterial layer using structural transient dynamic analysis in ANSYS. Four combinations of stent deployment, i.e. the Sinusoidal stent expanded by the offset balloon, the Sinusoidal stent expanded by the ordinary cylindrical balloon, the Asymmetric stent expanded by the offset balloon, and the Asymmetric stent expanded by the ordinary cylindrical balloon, are generated for this comparative study. Multilayer material properties from recent in vitro experiments are adopted for the surrounding arterial layer, such as a fibrous cap, lipid core, diseased-healthy intima, and diseased-healthy media. In order to address plaque vulnerability, the Cauchy stresses and Hencky strains are used for stress measure because of convenience in comparison with the uniaxial/biaxial tension test data. The location-specific threshold value from the diseased human carotid artery is adopted for rupture criteria. The simulation indicated that as regards the eccentric plaque, the plaque vulnerability is caused by the plaque shape and components rather than caused by the geometrical structure of the stent or balloon expansion method. Nevertheless, the non-symmetric inflation of balloon, which leads against the plaque, contributed to an increase in the vulnerability of fibrous cap of fibroatheroma plaque.
Keywords: Tissue rupture, asymmetric, eccentricity, carotid artery stenting, FEM
DOI: 10.3233/BME-191054
Journal: Bio-Medical Materials and Engineering, vol. 30, no. 3, pp. 309-322, 2019
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]