Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Hayatsu, Yukihiroa | Watanabe, Koyua | Sasaki, Konosukea | Masaki, Naokia | Katahira, Shintaroa | Kumagai, Kiichiroa | Kawamoto, Shunsukea | Ohmi, Toshihitob | Yokobori Jr., A. Toshimitsuc | Saiki, Yoshikatsua;
Affiliations: [a] Division of Cardiovascular Surgery, Graduate School of Medicine, Tohoku University, Sendai, Japan | [b] Department of Mechanical Engineering, Shonan Institute of Technology, Fujisawa, Japan | [c] Strategic Innovation and Research Center, Laboratory of Strength and Science, Teikyo University, Tokyo, Japan
Correspondence: [*] Corresponding author: Yoshikatsu Saiki, MD, PhD, Professor and Chairman, Division of Cardiovascular Surgery, Graduate School of Medicine, Tohoku University, 1-1 Seiryocho, Aoba, Sendai, Japan. Tel.: +81 22 717 7222; Fax: +81 22 717 7227; E-mail: [email protected]
Abstract: OBJECTIVE:We aimed to develop a novel ultrasound system and examine its feasibility for noninvasively detecting thoracic aortic aneurysm (TAA) in clinical settings. METHODS:We developed a novel ultrasound system consisting of a modified console and data analysis algorithm. The exploratory study included 100 patients hospitalized for elective cardiovascular surgery. After admission, the arterial pulse waveform at the left carotid artery was acquired using the novel system. Based on these data, we inferred the presence of TAA based on arterial viscoelasticity and instability, which are reflected into the time-averaged trajectory of deformation of the blood vessel wall caused by disturbance of blood flow. Meanwhile, all patients underwent computed tomography as preoperative screening to confirm the presence of TAA. The sensitivity and specificity of TAA detection using the novel ultrasound system were calculated. RESULTS:The datasets from 37 patients were not suitable for analysis and were thus discarded. Based on computed tomography findings, 40 patients were categorized into the aneurysm group while 23 were judged not to have and aortic aneurysm. On the other hand, 44 patients were diagnosed as having TAA based on ultrasound findings obtained using the novel system. The overall sensitivity and specificity of the ultrasound system were 0.83 and 0.52, respectively. CONCLUSION:We successfully developed a novel system for noninvasive, ultrasound-based evaluation of the left carotid artery to detect TAA. Although improvements to the probe and diagnostic algorithm are warranted, this device has potential utility for mass screening to detect asymptomatic TAA as part of community-level healthcare programs.
Keywords: Thoracic aortic aneurysm, ultrasound, non-invasive detection, peripheral artery
DOI: 10.3233/BME-191047
Journal: Bio-Medical Materials and Engineering, vol. 30, no. 2, pp. 231-241, 2019
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]