Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Peerapattana, Jomjaia | Hattori, Yusukeb | Otsuka, Makotob;
Affiliations: [a] Center for Research and Development of Herbal Health Products, Faculty of Pharmaceutical Sciences, Khon Kaen University, Khon Kaen, Thailand | [b] Research Institute of Pharmaceutical Sciences, Faculty of Pharmacy, Musashino University, Shinmachi, Nishi-Tokyo, Japan
Correspondence: [*] Corresponding author: Makoto Otsuka. Tel./Fax: 81424688658; E-mail: [email protected]
Abstract: BACKGROUND:In order to manufacture pharmaceutical products, real-time monitoring in the manufacturing process is necessary, but large equipment cost is required to achieve it. OBJECTIVE:The aim of this research is to use ultra-violet-visible spectroscopy along with chemometrics procedure to simultaneously carry out quantitative analysis of indomethacin (IMC) and benzoic acid (BA) in the gel during pharmaceutical manufacturing process. METHODS:The gel preparations contained 0.1–1.5% IMC, 0.015–0.225% BA, 2% carbopol® 941 and 95% ethanol solution. The calibration models were constructed using the partial least square regression (PLS). RESULTS:The relationships of the measured and predicted concentrations for both IMC and BA had linear plots. The developed PLS calibration models were used to monitor the IMC and BA concentrations during mixing of the gels by the planetary centrifugal and conventional mixers, respectively. IMC and BA were gradually dispersed, dissolved and completely homogeneous within 30 min by the centrifugal mixer. In contrast, IMC and BA were slowly dispersed, dissolved and completely homogeneous at more than 60 min by the conventional mixer. CONCLUSIONS:The ultra-violet-visible spectrophotometric method couples with multivariate chemometric techniques for quantitative data analysis were successfully applied for the simultaneous determination of major component IMC and trace component BA in the gel.
Keywords: Ultra-violet-visible spectroscopy, indomethacin, benzoic acid, process monitoring, partial least square regression, process analysis technology
DOI: 10.3233/BME-181034
Journal: Bio-Medical Materials and Engineering, vol. 30, no. 1, pp. 73-84, 2019
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]