Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Kang, Kyoung-Taka | Son, Juhyuna | Kwon, Sae Kwangb | Kwon, Oh-Ryongb | Koh, Yong-Gonb;
Affiliations: [a] Department of Mechanical Engineering, Yonsei University, 50 Yonsei-ro, Seodaemun-gu, Seoul, 03722, Republic of Korea | [b] Department of Orthopaedic Surgery, Joint Reconstruction Center, Yonsei Sarang Hospital, 10 Hyoryeong-ro, Seocho-gu, Seoul, 06698, Republic of Korea
Correspondence: [*] Corresponding author: Yong-Gon Koh, M.D., Joint Reconstruction Center, Department of Orthopaedic Surgery, Yonsei Sarang Hospital, 10 Hyoryeong-ro, Seocho-gu, Seoul, 03722, Republic of Korea. Tel.: +82 2 2023 5541; Fax: +82 2 2023 5597; E-mail: [email protected]
Abstract: BACKGROUND:Medial unicompartmental knee arthroplasty (UKA) could be concerned with wear of the cartilage or the wear in the polyethylene (PE) insert. Mechanical alignment determines the biomechanical effect in the long term. However, previous computational studies all found that femoral and tibial components alignment in the UKA were rare, and the results varied. OBJECTIVE:The purpose of this study was to evaluate the biomechanical effect of the femoral and tibial component coronal alignment in varus and valgus conditions through computational simulation. METHODS:A three-dimensional finite element model of the intact knee was constructed from medical image data of one healthy subject. A medial UKA model of neutral position and various coronal components was developed from the intact knee joint model. The tibial varus-femoral valgus and tibial valgus-femoral varus conditions were analyzed with parallel component angles of 3°, 6° and 9° by using validated finite element models. We considered the contact stresses in the PE inserts and articular cartilage and the force on collateral ligament under gait cycle condition. RESULTS:Compared to the contact stress in the neutral position model, the contact stress on the PE insert increased in both tibial varus-femoral valgus and tibial valgus-femoral varus models. These trends were also observed in the case of the articular cartilage in remain compartment. However, the contact stress on the PE insert and articular cartilage increased largely in the tibial valgus-femoral varus model than in the tibial varus-femoral valgus model. The forces on the medial and lateral collateral ligaments increased in the tibial valgus-femoral varus model, whereas in the tibial varus-femoral valgus model, the forces decreased compared to the forces in the neutral position. The force on the anterior lateral ligament and popliteofibular ligament increased in the tibial varus-femoral valgus model as compared to the neutral position. CONCLUSIONS:Our study suggests that neutral alignment or less than 3° tibial varus-femoral valgus alignment in the coronal plane can be recommended in medial UKA to reduce the postoperative complications and to enhance the life expectancy of implants.
Keywords: Unicompartmental knee arthroplasty, coronal malalignment, varus, valgus, finite element analysis
DOI: 10.3233/BME-181015
Journal: Bio-Medical Materials and Engineering, vol. 29, no. 5, pp. 651-664, 2018
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]