Article type: Research Article
Authors: Aherwar, Amita | Bahraminasab, Marjanb; *
Affiliations: [a] Mechanical Engineering Department, Madhav Institute of Technology and Science, Gwalior-474005, India | [b] Department of Tissue Engineering and Applied Cell Sciences, School of Medicine, Semnan University of Medical Sciences, Semnan, Iran
Correspondence: [*] Corresponding author. Tel.: +98 2333435901; E-mails: [email protected], [email protected].
Abstract: Biomaterials are continuously being developed to overcome the drawbacks of existing materials and provide improved function in artificial organs. Currently Co–Cr based alloys are used in many medical applications such as hip and knee implants which still require modification to better perform. In this article, therefore, the influence of tungsten allying element on electrochemical corrosion resistance and biocompatibility behaviour of a recently developed Co-30Cr-4Mo-1Ni alloy composition were investigated. The tungsten modified alloys were prepared by using a high temperature vertical vacuum casting technique at five different weight percentages (0–4wt.% tungsten). The electrochemical corrosion behaviour of all the samples under NaCl solution was studied by using potentiodynamic scan method. The corrosion characteristics were investigated in terms of corrosion potential (Ecorr) and corrosion current density (Icorr). From the results of the analysis, it was observed that out of all samples, an alloy with 2wt.% of tungsten in composition (i.e. Co-30Cr-4Mo-1Ni-2W) exhibited better corrosion resistance. Furthermore, histopathological evaluations in subcutaneous tissue were performed in rats according to the standard ISO 10993 to examine the biocompatibility of the prepared samples. The results showed no evidence of inflammatory cell migration, no epidermal necrosis, no vacuolar degeneration of basal cell, no adnexal atrophy and vesicle formation of any samples. The obtained findings indicate that Co-30Cr-4Mo-1Ni-2W can be used in biomedical applications including femoral component of hip and knee implants.
Keywords: Co–Cr alloy, corrosion, biocompatibility, tungsten, femoral component material, animal model
DOI: 10.3233/BME-171706
Journal: Bio-Medical Materials and Engineering, vol. 28, no. 6, pp. 687-701, 2017
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]