Affiliations: [a] Department of Oncology, Poznan University of Medical Sciences, Poznan, Poland | [b] Department of Human Nutrition and Hygiene, Poznan University of Life Sciences, Poznan, Poland | [c] Department of Biophysics, Poznan University of Medical Sciences, Poznan, Poland | [d] Department of Physics, Adam Mickiewicz University, Poznan, Poland
Correspondence: [*] Address for correspondence: Marcin Mardas, MD, PhD, Department of Oncology, Poznan University of Medical Sciences, ul. Szamarzewskiego 82/84, 60-569 Poznan, Poland. Tel.: +48 61854 9020; Fax: +48 61854 9013; E-mail: [email protected].
Abstract: The increased use of allograft tissue for musculoskeletal repair has brought more focus to the safety of allogenic tissue and the efficacy of various sterilization techniques. The currently available literature contains few examples of studies on long-lasting strains of bones but no example for irradiated bones. In this study the bovine femurs from a 2-year-old animal were machine cut and irradiated with the doses of 10, 15, 25, 35, 45 and 50 kGy. The dynamic mechanical analysis was performed at 1 Hz at the room temperature in a 3-point bending configuration for 2880 minutes. The final values of E′ and E″ were dose independent but they were reached at different periods. For this reason, so called “critical point” was introduced for the further analysis. All the examined sample groups were characterized by statistically significant lower values of the critical point in comparison with the control samples (p<0.05) but the biggest differences were observed between the control samples and the samples irradiated with the doses of 10, 15 and 25 kGy. Current results and literature review suggest that the dose of 35 kGy is the optimal dose for ionizing radiation sterilization.
Keywords: Bone, radiation, sterilization, DMA (Dynamic Mechanical Analysis)
DOI: 10.3233/BME-151536
Journal: Bio-Medical Materials and Engineering, vol. 25, no. 4, pp. 397-403, 2015
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]