Article type: Research Article
Authors: Yamashita, Keigoa | Suzuki, Shukob; d; * | Tabayashi, Nobuokia | Abe, Takehisaa | Hayata, Yoshihiroa | Hirose, Tomoakia | Hiraga, Shuna | Niwa, Kosukea | Fukuba, Ryoheia | Takeda, Maikoc | Ikada, Yoshitob; e | Taniguchi, Shigekia
Affiliations: [a] Department of Thoracic and Cardiovascular Surgery, School of Medicine, Nara Medical University, Kashihara, Japan | [b] Biomedical Engineering, School of Medicine, Nara Medical University, Kashihara, Japan | [c] Diagnostic Pathology, School of Medicine, Nara Medical University, Kashihara, Japan | [d] Queensland Eye Institute, Brisbane, Australia | [e] Kyoto University, Kyoto, Japan
Correspondence: [*] Address for correspondence: Shuko Suzuki, PhD, Queensland Eye Institute, 140 Melbourne Street, South Brisbane, QLD 4101, Australia. Tel.: +61 3239 5025; Fax: +61 3844 1914; E-mail: [email protected].
Abstract: BACKGROUND: Anastomotic needle hole bleeding is a frequently encountered problem in cardiovascular surgeries. OBJECTIVE: To examine the feasibility of crosslinked gelatin glue as an anastomotic needle hole sealant in comparison with fibrin glue. METHODS: The in vitro burst water pressures were measured for gelatin and fibrin glue sealed needle holes of expanded polytetrafluoroethylene (ePTFE) or collagen coated woven polyester grafts. For in vivo investigations, abdominal aorta-ePTFE graft anastomoses of heparinized beagle dogs were sealed by gelatin or fibrin glue and hemostatic efficacy was judged. The implanted sites were re-examined 4 weeks postoperatively. RESULTS: The in vitro burst water pressures of gelatin glue sealed needle holes of both grafts were higher than those sealed by fibrin glue. For in vivo canine studies, hemostasis was successful for all gelatin glue applied suture lines, but not two out of three fibrin glue treated sites when 3-0 polypropylene suture was employed. Although adhesions of surrounding tissues were intense for all sites 4 weeks postoperatively, inflammation was more severe for the fibrin glue group compared to those of gelatin glue. CONCLUSIONS: Gelatin glue was found to be an effective and safe sealant for accomplishing hemostasis of anastomotic needle holes of vascular grafts.
Keywords: Gelatin, sealant, fibrin glue, needle hole hemostasis
DOI: 10.3233/BME-151534
Journal: Bio-Medical Materials and Engineering, vol. 25, no. 4, pp. 361-370, 2015
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]