Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Lewis, Gladius
Affiliations: Department of Mechanical Engineering, The University of Memphis, Campus Box 526576, Memphis, TN 38152, USA
Abstract: The composition and viscosity of an acrylic bone cement have both been identified in the literature as being parameters that affect the mechanical properties of the material and, by extension, the in vivo longevity of cemented arthroplasties. The objective of the present study was to determine the relative influence of these parameters on a key cement mechanical property; namely, its fracture toughness. Two sets of cements were selected purposefully to allow the study objective to be achieved. Thus, one set comprised two cements with very similar compositions but very different viscosities (Cemex^{\mathrm{TM}} RX, a medium‐viscosity brand, and Cemex Isoplastic, a high‐viscosity brand) while the other set comprised two cements with similar viscosities but with many differences in composition (Cemex Isoplastic and CMW® 1). Values of the fracture toughness (as determined using chevron‐notched short rod specimens) [K_{\mathrm{ISR}}] obtained for Cemex RX and Cemex Isoplastic were 1.83 ± 0.12 and 1.85 ± 0.12 MPa\surdm, respectively, with the difference not being statistically significant. The K_{\mathrm{ISR}} values obtained for Cemex Isoplastic and CMW^{\mathrm{TM}}1 were 1.85 ± 0.12 and 1.64 ± 0.18 MPa\surdm, respectively, with the difference being statistically significant. Thus, the influence of cement composition on its K_{\mathrm{ISR}} is more marked relative to the influence of cement viscosity. Explanations of this finding are offered, together with comments on the implications of the results for the in vivo longevity of cemented arthroplasties.
Keywords: Acrylic bone cement, fracture toughness, cement composition, cement viscosity
Journal: Bio-Medical Materials and Engineering, vol. 10, no. 1, pp. 1-11, 2000
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]