Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Subtitle: Comparison between total hip arthroplasty and bipolar endoprosthetic arthroplasty
Article type: Research Article
Authors: Isobe, Yasuyuki; | Okuno, Makoto | Otsuki, Takeo | Yamamoto, Kichizo
Affiliations: Department of Orthopedic Surgery, Faculty of Medicine, Tottori University, Tottori, Japan
Note: [] Address for correspondence: Yasuyuki Isobe, Department of Orthopedic Surgery, Faculty of Medicine, Tottori University, 36‐1 Nishi‐machi, Yonago 683, Japan. Tel.: (0859) 34 8115; Fax: (0859) 34 8093.
Abstract: The present study was undertaken to serially observe gait of patients after hip arthroplasty, using quantitative gait analysis, and to compare it between patients after total hip arthroplasty (THA) and those after bipolar endoprosthetic arthroplasty (BEA). The subjects were 53 women with unilateral osteoarthritis of the hip. Thirty‐one of them underwent THA (mean age: 59.5 years) and 22 underwent BEA (mean age: 58.0 years). The stance time and characteristic parameters calculated from the vertical component of floor reaction force (FRF) were analyzed by use of FRF plate. The stance time, which indirectly represents the walking speed, tended to decrease for one year after THA and for 3 years after BEA. The decrease in this parameter was greater on the unaffected side than on the affected side. The deceleration effect and the weighing‐off effect are indicators useful for observation of gait recovery. Significant differences in these indicators between the unaffected and affected sides were seen for one year after THA and 3 years after BEA. This indicates that cadence and balance of the gait recovers earlier after THA than after BEA.
Keywords: Gait analysis, floor reaction force, total hip arthroplasty, bipolar endoprosthesis, osteoarthritic hip
Journal: Bio-Medical Materials and Engineering, vol. 8, no. 3-4, pp. 167-175, 1998
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]