Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Yamamoto, Noritaka; | Hayashi, Kozaburo
Affiliations: Department of Mechanical Engineering, Faculty of Science and Engineering, Ritsumeikan University, Kusatsu, Siga 525‐8577, Japan | Division of Mechanical Science, Department of Systems and Human Science, Graduate School of Engineering Science, Osaka University, Toyonaka, Osaka 560‐8531, Japan
Note: [] Address correspondence and reprint requests to: Noritaka Yamamoto, Ph.D., Department of Mechanical Engineering, Faculty of Science and Engineering, Ritsumeikan University, 1‐1‐1 Noji‐higashi, Kusatsu, Shiga 525‐8577, Japan. Tel.: +81 77 561 2878; Fax: +81 77 561 2665; E‐mail: [email protected].
Abstract: The tensile properties of the rabbit patellar tendon were determined at a very high extension rate (560 mm/s), and were compared to those obtained at lower rates (53 and 0.33 mm/s). A closed‐loop servo‐hydraulic material test machine was used for the tensile tests at the rates of 560 and 53 mm/s. Strain was determined using a high‐speed video dimension analyzer consisting of a line sensor camera, control unit, and image processing board. For the tests at 0.33 mm/s, a conventional tensile tester and video dimension analyzer were utilized. The tensile strength and strain at failure of the tendon increased by 51 and 77%, respectively, with increase in the extension rate from 0.33 to 560 mm/s (from 0.566 to 1250%\,s^{-1} in strain rate); these parameters increased by 35 and 42%, respectively, with the rate change from 0.33 to 53 mm/s (from 0.566 to 151%\,s^{-1}). However, there were no significant differences in the tangent modulus among the three rates. These results indicate that tensile strength and strain at failure increase with increase in strain rate, with no change in tangent modulus.
Keywords: Mechanical properties, patellar tendon, tensile test, high strain rate, rabbit
Journal: Bio-Medical Materials and Engineering, vol. 8, no. 2, pp. 83-90, 1998
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]