Article type: Research Article
Authors: Li, Jianguo;
Affiliations: Center for Oral Biology at Novum, Karolinska Institute, Box 4064, S‐141 04 Huddinge, Sweden
Note: [] Correspondent address: Dr. Li Jianguo, COB, Box 4064, S‐141 04 Huddinge, Sweden. Tel.: +46 8 746 0235; Fax: +46 8 779 3166; E‐mail: [email protected].
Abstract: The purpose of this study was to compare the morphology of the tissues remaining on smooth and dimpled surfaces of a ceramic composite of zirconia–hydroxyapatite (TZ‐2Y/25HA) with commercially pure titanium (cp Ti) after a push‐out test. The tissue–material interface was viewed on the specimens without being tested mechanically. Cylindrical implants were inserted in the femurs of rabbits for three months. Each femur received three implants. After sacrificing the animals, the target tissues were collected and divided into two groups: group I was fixed in 4% formalin immediately, and group II was tested mechanically by push‐out before fixation. Specimens were then dehydrated for SEM observation. The results showed that no remaining tissue appeared on the smooth cp Ti surface, whereas remaining tissues, mineralized and collagenous tissues, were seen on the smooth surface of the TZ‐2Y/25HA. New bone had grown into and filled the most of dimple spaces of both the cp Ti and TZ‐2Y/25HA implant. A submicron gap between the bone and cp Ti was found, whereas the TZ‐2Y/25HA was occasionally in direct contact with new bone. Thus TZ‐2Y/25HA showed an intimate contact to bone in some areas, and cp Ti showed an unmineralized tissue separated interface to bone continuously. Taken together, the laser machining seems to have no adverse effects on tissue response and is a potential technique for producing micro‐patterned surfaces on dental and medical implants.
Keywords: Anti‐rotation, bone ingrowth, dimpled implant surface
Journal: Bio-Medical Materials and Engineering, vol. 7, no. 6, pp. 379-385, 1997
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]