Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Issue title: Frontiers in Biomedical Engineering and Biotechnology – Proceedings of the 2nd International Conference on Biomedical Engineering and Biotechnology, 11–13 October 2013, Wuhan, China
Article type: Research Article
Authors: Zhang, Xubing; | Zhang, Penglin; | Hirai, Shinichi
Affiliations: School of Public Administration, China University of Geosciences, Wuhan 430073, China | Department of Robotics, Faculty of Science and Engineering, Ritsumeikan University, Kusatsu, Shiga, 525-8577, Japan | School of Remote Sensing and Information Engineering, Wuhan University, Wuhan 430079, China
Note: [] Correspondence Author. E-mail:[email protected]
Abstract: Due to the nonlinear and nonuniform local deformation of nonrigid tissues, it is difficult to match a number of feature points distributing somewhat uniform in the tissues from MR images for deformation measurement. This paper proposes TSSC (TPS-SURF-SAC-Clustering) based method of feature point matching and elimination of mismatching. First, Fast-Hessian and Harris operator are utilized to extract the feature points in the initial MR image, and the matching region is identified by TPS transformation model for every query point in the deformed image. Then the SURF descriptors and the proposed Spatial Association Correspondence (SAC) method are combined to match the feature points. Finally, by clustering the coordinate differences between the matching points obtained by TPS-SURF-SAC and the matching points calculated by TPS model, most incorrectly matched points are eliminated. After every iterative processing of matching and mismatching elimination, the updated TPS model becomes more accurate and more correctly so that the matched points can be identified than those of last iteration. The experimental results show that the proposed SAC was efficient and that TSSC based method outperformed the single SURF or SIFT method.
Keywords: Feature point, extraction, matching, deformation
DOI: 10.3233/BME-130924
Journal: Bio-Medical Materials and Engineering, vol. 24, no. 1, pp. 1227-1237, 2014
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]