Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Issue title: Frontiers in Biomedical Engineering and Biotechnology – Proceedings of the 2nd International Conference on Biomedical Engineering and Biotechnology, 11–13 October 2013, Wuhan, China
Article type: Research Article
Authors: Wang, Rui-hao | Zhang, Shu-xu; | Zhou, Ling-hong | Zhang, Guo-qian | Yu, Hui | Lin, Xiao-dan | Lin, Shengqu
Affiliations: Radiotherapy Center, Affiliated Tumor Hospital of Guangzhou Medical University, Guangzhou, China | School of Biomedical Engineering, Southern Medical University, Guangzhou, China | Department of Radiation Oncology, Affiliated Tumor Hospital of Guangzhou Medical University, Guangzhou, China
Note: [] Email:[email protected].
Abstract: The aims of this study were to evaluate the volume and dosimetric variations during IMRT for locally advanced NPC and to identify the benefits of a two-phase adaptive IMRT method. Twenty patients with locally advanced NPC having received IMRT treatment were included. Each patient had both an initial planning CT (CT-1) and a repeated CT scan (CT-2) after treatment at a dose of 40 Gy. Three IMRT planning scenarios were compared: (1) the initial plan on the CT-1 (plan-1); (2) the hybrid plan recalculated the initial plan on the CT-2 (plan-2); (3) the replan generated on the CT-2 being used to complete the course of IMRT (plan-3). The mean gross target volume and mean volumes of the positive neck lymph nodes, high-risk clinical target volume, and the left and right parotid glands significantly decreased by 30.2%, 45.1%, 21.1%, 14.7% and 18.2%, respectively on the CT-2. Comparing plan-2 with plan-1, the dose coverage of the targets remained unchanged, whereas the dose delivered to the parotid glands and spinal cord increased significantly. These patients with locally advanced NPC might benefit from replanning because of the sparing of the parotid glands and spinal cord.
Keywords: Nasopharyngeal carcinoma, intensity-modulated radiotherapy, anatomic changes, adaptive replanning
DOI: 10.3233/BME-130923
Journal: Bio-Medical Materials and Engineering, vol. 24, no. 1, pp. 1217-1225, 2014
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]