Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Sugita, Shukei | Matsumoto, Takeo;
Affiliations: Center for Fostering Young and Innovative Researchers, Nagoya Institute of Technology, Nagoya, Japan | Department of Mechanical Engineering, Graduate School of Engineering, Nagoya Institute of Technology, Nagoya, Japan
Note: [] Address for correspondence: Takeo Matsumoto, PhD, Department of Mechanical Engineering, Graduate School of Engineering, Nagoya Institute of Technology, Gokiso-cho, Showa-ku, Nagoya 466-8555, Japan. Tel./Fax: +81 52 735 5049; E-mail: [email protected]
Abstract: There is growing evidence of heterogeneous distribution of collagen fibers in the aortic wall. To investigate the effects of collagen microstructure on local aortic wall deformation, porcine thoracic aortas were sliced into 100 μm-thick sections perpendicular to their radial direction and stretched biaxially with a laboratory-made tensile tester under a microscope equipped with a birefringence imaging system. Strain tensor components were calculated from fluorescent images of the cell nuclei for each 50×50 μm2 area. Retardance Ret and slow axis azimuth θ were measured as indices of collagen density and fiber direction, respectively. Aortic wall deformation was highly heterogeneous: standard deviations of strains were significantly larger, by 3–5 times, in aortic slices than in homogeneous silicone sheets. A significant negative correlation was found between maximum principal strain and Ret (R=−0.077), and a positive correlation between minimum principal strain direction and θ (R=0.345). These indicate that the aorta is less distensible in areas with higher collagen density and in the direction of collagen fiber alignment. Microscopic heterogeneity may induce heterogeneous responses of smooth muscle cells and have crucial effects on mechanical homeostasis in the aortic wall.
Keywords: Artery structure, biaxial stretch test, birefringence, connective tissue, mechanical properties
DOI: 10.3233/BME-130771
Journal: Bio-Medical Materials and Engineering, vol. 23, no. 6, pp. 447-461, 2013
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]