Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Wen, Xuejun; | Zhang, Ning | Li, Xiaohe | Cao, Zhengwang
Affiliations: Laboratory of Metallic Biomaterials, Department of MSE, Zhejiang University, Hangzhou, 310027, P.R. China
Note: [] Corresponding author: Mr. Xuejun Wen, Box 165, Zhejiang University, Hangzhou, 310027, P.R. China. Tel.: 0086 571 7990405(Home) or 0086 571 5172244, Ext. 2702(Office); Fax: 0086 571 7951358; E-mail: [email protected].
Abstract: By means of electrochemical and quantitative histomorphometric methods, the corrosion resistance and tissue biocompatibility of Ti50Ni50 and Ti50Ni50-xCux (x = 1, 2, 4, 6, 8) were investigated. It is discovered that the repassivation potential of Ti50Ni50-xCux (x = 2, 4, 6, 8) alloys is about 200 mV higher than that of Ti50Ni50 alloy. Namely, the addition of Cu raises the repassivation potential of TiNi shape memory alloys and improves their corrosion resistance. Pitting potentials of Ti50Ni50 and Ti50Ni50-xCux (x = 1, 2, 4, 6, 8) alloys increase with solution pH value, but the repassivation potentials keep constant. The adding of Cu has no obvious influence on pitting potential (Epit) of TiNi alloys, meanwhile, the corrosion potential and corrosion rate of Ti50Ni50-xCux (x = 1, 2, 4, 6, 8) alloys are irrelevant to its Cu content and the values are almost the same as those of TiNi alloys. The connective tissue layer covering the plates is statistically significantly thicker for Ti50Ni42Cu8 plates (p < 0.05) than that of Ti50Ni50, Ti50Ni48Cu2, Ti50Ni44Cu6 plates after one month. The numbers of connective tissue cells, polynucleated cells, macrophages and round cells are higher for Ti50Ni42Cu8 plates than those of the other three types of plates, but no statistically significant differences are detected. There are no significant differences on tissue reaction parameters after two and three months among four alloys. After one, two and three months implantation, no corrosion is observed on the plates surfaces. A preliminary conclusion can be drawn that Ti50Ni50-xCux (x = 2, 6, 8) shape memory alloys have good biocompatibility.
Keywords: Shape memory alloy, electrochemistry, corrosion, biocompatibility, histomorphometry
DOI: 10.3233/BME-1997-7101
Journal: Bio-Medical Materials and Engineering, vol. 7, no. 1, pp. 1-11, 1997
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]