Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Afshari, Elnaz | Najarian, Siamak; | Simforoosh, Nasser
Affiliations: Biomedical Engineering, Artificial Tactile Sensing and Robotic Surgery Laboratory, Biomedical Faculty, Amirkabir University of Technology, Tehran, Iran | Urology Department, Shahid Beheshti University of Medical Sciences, Shahid Labbafi Nejad Hospital, Tehran, Iran
Note: [] Address for correspondence: Siamak Najarian, Artificial Tactile Sensing and Robotic Surgery Laboratory, Faculty of Biomedical Engineering, Amirkabir University of Technology (Tehran Polytechnic), No. 424, Hafez Ave., PO Box 15875-4413, Tehran, Iran. Tel.: +9821 6454 2378; Fax: +9821 8848 8186; E-mail: [email protected].
Abstract: Artificial tactile sensing is a novel method for obtaining different characteristics of a hard object embedded in a soft tissue. In this regard, artificial palpation is one of the most valuable achievements of artificial tactile sensing that can be used in various fields of medicine and more specifically in surgery. In this study, considering the present problems and limitations in kidney-stone-removal laparoscopy, a new application will be presented for artificial tactile sensing approach. Having imitated surgeon's palpation during open surgery and modeled it conceptually, indications of stone existence that appear on the surface of kidney (due to exerting mechanical load) were determined. A number of different cases were created and solved by the software. Using stress distribution contours and stress graphs, it is illustrated that the created stress patterns on the surface of kidney not only show the existence of stone inside, but also its exact location. In fact, the reliability and accuracy of artificial tactile sensing method in detection of kidney stone during laparoscopy is demonstrated by means of finite element analysis. Also, in this paper, the functional principles of tactile system capable of determining the exact location of stone during laparoscopy will be presented.
Keywords: Artificial tactile sensing, artificial palpation, kidney stone, laparoscopic surgery
DOI: 10.3233/BME-2010-0640
Journal: Bio-Medical Materials and Engineering, vol. 20, no. 5, pp. 261-267, 2010
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]