Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Cheng, Fang-Hsin; | Shih, Shih-Liang | Chou, Wen-Kai | Liu, Chien-Lin | Sung, Wen-Hsu | Chen, Chen-Sheng;
Affiliations: Department of Physical Therapy and Assistive Technology, National Yang Ming University, Taipei, Taiwan | Department of Physical Medicine and Rehabilitation, Taipei-Veterans General Hospital, Taipei, Taiwan | Department of Orthopaedic Surgery, Taipei-City Hospital, Taipei, Taiwan | Institute of Biomedical Engineering, National Taiwan University, Taipei, Taiwan | Department of Orthopaedic Surgery, Taipei-Veteran General Hospital, Taipei, Taiwan
Note: [] Address for correspondence: Chen-Sheng Chen, PhD, Department of Physical Therapy and Assistive Technology, National Yang Ming University, 155, Sec. 2, Li-Nung St., Taipei, Taiwan. E-mail: [email protected].
Abstract: The role of the vertebral body's rotation and the loading conditions of the brace has not been clearly identified in adolescent idiopathic scoliosis. This study aimed to implement a finite element (FE) model of C-type scoliotic spines to investigate the influence of different loading conditions on variations of Cobb's angle and the vertebral rotation. The scoliotic FE model was constructed from C7 to L5, and its geometry was the right thoracic type (37.4°) with an apex over T7. Three loading conditions included a medial–lateral (ML) and anteroposterior (AP) force with a magnitudes of 100–0, 80–20 and 60–40 N. Those forces were respectively applied over the 6th, 7th and 8th ribs. According to an analysis of Cobb's angle, the 100 N ML force that was applied over the 8th rib could achieve the best correction effect. Furthermore, the ML force was dominant in alterations of Cobb's angle, whereas the AP force was dominant in alterations of the axial vertebral rotation. Additionally, the level below the apex was the most appropriate level to apply the force to correct C-type scoliosis.
Keywords: Scoliosis, loading condition, Cobb's angle, finite element analysis
DOI: 10.3233/BME-2010-0639
Journal: Bio-Medical Materials and Engineering, vol. 20, no. 5, pp. 251-259, 2010
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]