Article type: Research Article
Authors: Shabalovskaya, S.; ; | Anderegg, J. | Rondelli, G. | Vanderlinden, W. | De Feyter, S.
Affiliations: Ames Laboratory, Iowa State University, Ames, IA, USA | Institute of Energy and Interphases, CNR, Milan, Italy | Katholieke Universiteit Leuven, Belgium
Note: [] Address for correspondence: Dr. Svetlana Shabalovskaya, Kasteelpark Arenberg 44, MTM, Katholieke University Leuven, B-3001 Leuven, Belgium. Tel.: +32 16 32 1233; Fax: +32 16 32 1992; E-mail: [email protected].
Abstract: Comparative fibrinogen adsorption and platelet morphology were evaluated on a wide array of well-characterized Nitinol surfaces (polished, chemically etched, boiled in water, electropolished in different electrolytes and heat treated). XPS, SEM, AFM, atomic adsorption spectroscopy and electrochemistry were employed to acquire information on surface chemistry, topography and Ni release. Obtained surfaces, of various topographies and crystallinity from mostly amorphous to nano-crystalline with Ni concentration from 1 to 8%, induced Ni release into biological medium in a subtoxic range (0–11 ng/ml/cm2). Fibrinogen adsorption to Nitinol surfaces ranged from that characteristic to pure Ni (130 ng/cm2) to pure Ti (300 ng/cm2). It was directly proportional to the Ti surface concentration and correlated with open circuit potential related to surface charge. Human platelet morphology varied from round to fully spread depending on surface treatment. Base layer of fully spread cells detected on all surfaces could be even and smooth with no propensity for thrombosis or sticky causing platelet aggregation and thrombus-like structures. Using appropriate surface treatments thrombogenicity of Nitinol can be manipulated to satisfy both the requirements for stents and defect closures.
Keywords: NiTi surface topography, roughness, nickel release, fibrinogen, platelets, open circuit potential, thrombogenicity
Journal: Bio-Medical Materials and Engineering, vol. 18, no. 1, pp. 1-14, 2008
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]