Affiliations: Frontier Research and Development Center, Tokyo Denki University, Ishizaka, Hatoyama, Hiki, Saitama 350-0394, Japan | Nihon Shinkan co. ltd., 1-10-22, Nakano, Niiza, Saitama 352-0005, Japan | Applied Systems Engineering, Graduate School of Science and Engineering, Tokyo Denki University, Ishizaka, Hatoyama, Hiki, Saitama 350-0394, Japan
Note: [] Corresponding author. Tel.: +81 49 296 2911 (3761); Fax: +81 49 296 2925; E-mail: [email protected].
Abstract: Three-dimensional finite element analysis was performed for thin hydroxyapatite (HA) coated and titanium dental implants to study the effects on stress/strain distribution in the mandible with application of axial and oblique loads. The implants were of screw and cylinder types. With an axial load, the maximum equivalent bone stresses in the titanium implants were 21.5 and 29.0 MPa for the cylinder and screw types respectively, and the stress and strain distributions differed. For the cylinder type, the highest stress was located at the implant base, and for the screw type, it was located at the top edge of the first thread within the cortical bone. For the HA-coated cylinder and screw implants, the maximum equivalent bone stresses were 7.1 and 7.2 MPa respectively. The stress and strain distributions were similar, and the highest stress was located on the upper side of the cortical bone around the implant neck for both implants. Of the implants examined, the screw type HA-coated implant had the most uniform stress distribution in bone.
Keywords: Dental implant, finite element analysis, hydroxyapatite
Journal: Bio-Medical Materials and Engineering, vol. 16, no. 3, pp. 157-169, 2006
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]