Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Wei, Hung‐Wen | Chung, Ming‐Yen | WS Huang, Vincent | Cheng, Cheng‐Kung;
Affiliations: Orthopaedic Biomechanics Laboratory, Institute of Biomedical Engineering, National Yang Ming University, Taipei, Taiwan | Department of Orthopedics, Shin‐Kong Wu Ho‐Su Memorial Hospital, Taipei, Taiwan
Note: [] Corresponding author: Cheng‐Kung Cheng, PhD, Professor and Director, Orthopaedic Biomechanics Laboratory, Institute of Biomedical Engineering, National Yang‐Ming University, 155, Sec. 2, Li‐Nung Street, Taipei, Taiwan. Tel.: 886 2 28267020; Fax: 886 2 28202519; E‐mail: [email protected].
Abstract: The hip stem design based upon X‐ray films requires sufficient information in order to customize for the patient. If the errors are resulted from rotating angles, more X‐ray films may carry out the solution. The present study aimed to realize the improvement of multiple X‐ray films for hip stem design. Eight X‐ray films were taken from a volunteer. The characteristic length of X‐ray film was input into cosine function to derive the relative rotating angle of each X‐ray film. The combinations of 2, 4, 6, and 8 X‐ray films that included true AP view and lateral view were obtained to construct the corresponding stem. CT images were used to construct femur and stem model to verify the rotating angle of femur in each X‐ray film. A quantitative comparison was made between the hip stems for the fill ratio, fit gap and contact area. The results showed that the markers on the body surface would result in error and were unable to provide reference to the rotating angle of femur. The contact area and fill ratio of the stems designed by 6 or 8 X‐ray films would get closer to that by CT images. It is concluded that the rotation of the femur could be determined from the length of femoral neck as well as the distance between the tips of medial and lateral condyles. The use of 6 or more X‐ray films for custom‐made hip stem as a source of design is recommended in this study.
Keywords: Custom hip stem, X‐ray film, femur rotation
Journal: Bio-Medical Materials and Engineering, vol. 14, no. 2, pp. 193-202, 2004
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]