Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Sano, Hirotakaa; | Komatsuda, Tatsurob | Suzuki, Kazuhidec | Abe, Hirooa | Ozawa, Hiroshid | Kumagai, June | Yokobori Jr, Toshimitsu A.f
Affiliations: [a] Division of Orthopedics, Sendai City Hospital, Sendai, Japan | [b] North Sendai Orthopaedic Clinic, Sendai, Japan | [c] Department of Sports Medicine, Asao General Hospital, Kawasaki, Japan | [d] Department of Orthopaedic Surgery, Tohoku Medical and Pharmaceutical University, Sendai, Japan | [e] Department of Orthopaedic Surgery, Akaishi Hospital, Shiogama, Japan | [f] Laboratory of Strength of Material and Science, Advanced Comprehensive Research Organization, Teikyo University, Tokyo, Japan
Correspondence: [*] Corresponding author: Hirotaka Sano, Division of Orthopedics, Sendai City Hospital, 1-1-1Asuto Nagamachi, Taihaku-ku, Sendai, 982-8502, Japan. Tel.: +81 22 308 7111; Emails: [email protected], [email protected]
Abstract: BACKGROUND:There is a lack of consensus concerning the coracoid graft length in the modified Bristow procedure. OBJECTIVE:We attempted to determine the optimal graft length using the three-dimensional finite element method. METHODS:In a shoulder model with a 25% anterior glenoid defect, a coracoid graft of varying lengths (5, 10, 15, and 20 mm) was fixed using a half-threaded screw. First, a compressive load of 500 N was applied to the screw head to determine the graft failure load during screw tightening. Next, a tensile load (200 N) was applied to the graft to determine the failure load due to biceps muscle traction. RESULTS:In the screw compression, the failure loads in the 5-, 10-, 15-, and 20-mm models were 252, 370, 377, and 331 N, respectively. In the tensile load applied to the coracoid graft, the failure load exceeded 200 N for both the 5- and 10-mm models. CONCLUSION:The 5-mm graft had a high risk of fracture during intraoperative screw tightening. As for the biceps muscle traction, the 5- and 10-mm-grafts had a lower failure risk than the 15- and 20-mm-grafts. Therefore, we believe that the optimal length of the coracoid graft is 10 mm in the modified Bristow procedure.
Keywords: Coracoid graft length, anterior shoulder instability, modified Bristow procedure, failure load, compressive force, tensile stress
DOI: 10.3233/BME-230071
Journal: Bio-Medical Materials and Engineering, vol. 35, no. 1, pp. 65-75, 2024
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]