Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Hanabusa, Masaoa; | Kimura, Saoria | Sakaeda, Nanaa | Okawa, Kazuyoshia | Saito, Watarua | Yamamoto, Takatsugua
Affiliations: [a] Department of Operative Dentistry, School of Dental Medicine, Tsurumi University, Tsurumi, Tsurumi-ku, Yokohama, Japan
Correspondence: [*] Corresponding author: Masao Hanabusa, Department of Operative Dentistry, School of Dental Medicine, Tsurumi University, 2-1-3 Tsurumi, Tsurumi-ku, Yokohama 230-8501, Japan. E-mail: [email protected]
Abstract: BACKGROUND:Polymerization stress is a major problem in dental resin composite restorations. Two indentation fracture methods can be applied to evaluate the stress, however, they often calculate different values. OBJECTIVE:To compare polymerization stresses of dental composites determined by the two methods. METHODS:Glass disks with a central hole were used. Two indentation fracture methods (Methods 1 and 2) were employed to determine the polymerization stresses of low-shrinkage and bulk-fill composites. Method 1: Cracks were made in the glass surface at 300 μm from the hole. The hole was filled with the composite. Polymerization stresses at 30 min after filling were calculated from the lengths of crack extension. Method 2: The hole was filled with the composite. Cracks were introduced in the glass at 1,000 μm from the hole at 30 min after the polymerization and the stresses were calculated from the crack lengths. Stresses at composite-glass bonded interface were calculated from the stress values obtained by the two methods. RESULTS:The bulk-fill composite generated the smallest interfacial stress, and Method 1 revealed lower values than Method 2. CONCLUSIONS:The composites yielded relatively small stresses. Method 1 calculated smaller stress values, possibly affected by the lower threshold stress intensity factor.
Keywords: Stress, polymerization, composite, crack, indentation fracture
DOI: 10.3233/BME-211307
Journal: Bio-Medical Materials and Engineering, vol. 33, no. 4, pp. 259-268, 2022
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]