Article type: Research Article
Authors: Ozeki, K.a; | Nishio, H.a
Affiliations: [a] Major in Mechanical Systems Engineering, Graduate School of Science and Engineering, Ibaraki University, Nakanarusawa, Hitachi, Ibaraki, Japan
Correspondence: [*] Corresponding author: K. Ozeki. Tel.: +81 294 38 5040; Fax: +81 294 38 5047; E-mail: [email protected]
Abstract: BACKGROUND:In some treatments using multiple dental implants, the implants are inserted in the bone with splinted or non-splinted implant prostheses. There are some reports about the influence of the splinted and non-splinted implants on stress distribution in the bone using the finite element method (FEM), and there is a controversy in the literature regarding whether the splinted or non-splinted implants prostheses reduce the stress generated on the implant-surrounding bone more efficiently. Additionally, the simple shape of the jaw bones with limited bone area was used for FEM analysis in many studies at the expense of accurate analysis. OBJECTIVE:The aim of this study was to evaluate the difference in stress distribution in the bone between the splinted and non-splinted implants, and between completely and partially edentulous mandibles. METHODS:The implants were inserted in the first premolar, second premolar, and first molar regions of the partial and complete mandibles, and the splinted and non-splinted crowns were attached to the implants. Vertical load (100 N) or oblique load (70 N, 30° from its long axis towards the lingual) was applied on the first premolar. RESULTS:When vertical load was applied to the partially edentulous mandible model, the stress was concentrated intensively on the cortical bone around the first premolar regardless of whether splinted or non-splinted implants were used. On the other hand, the vertical load applied to the completely edentulous mandible model caused the stress to be concentrated intensively on the cortical bone around the first premolar with non-splinted implants. With respect to the oblique load, the stress was concentrated intensively on the cortical bone around the first premolar only with the non-splinted implants, in both the partial and complete mandibles. CONCLUSION:This study shows the different stress distributions of the cortical bone around the implants between the partial and complete mandible. This indicates that the complete mandible should be used for the analysis of bone stress distribution around the implants using FEM.
Keywords: Finite element method, splinted, non-splinted, dental implant
DOI: 10.3233/BME-201077
Journal: Bio-Medical Materials and Engineering, vol. 31, no. 1, pp. 19-33, 2020
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]