Article type: Research Article
Authors: Zaczyk, Marcina;
Affiliations: [a] Division of Design of Precision Devices, Institute of Micromechanics and Photonics, Faculty of Mechatronics, Warsaw University of Technology, Warsaw, Poland
Correspondence: [*] Address for correspondence: Marcin Zaczyk, Division of Design of Precision Devices, Institute of Micromechanics and Photonics, Faculty of Mechatronics, Warsaw University of Technology, Boboli 8, 02-525 Warsaw, Poland. Tel.: +48 22 234 8543; Fax. +48 22 2348601; E-mail: [email protected]
Abstract: BACKGROUND/OBJECTIVE:We present a description of an experiment in which the parameters describing the quality of the mandrel embedding an implant into a bone were determined. A method was developed that allows, from outside a living organism, the strength of the mandrel of the implant in the bone tissue to be determined. Using the proposed technique, we investigated how the mechanical properties of the bone affect the quality of the implant mandrel embedding in the bone tissue. MATERIALS AND METHODS:As part of the research work, we conducted 15 compression tests on previously prepared samples that reflected an uncemented endoprosthesis embedding in the proximal base of a femur bone. RESULTS:The results of the research showed that the load applied is dispersed between the mandrel and the bone tissue. The mechanical stability of the embedding affects the mechanical properties of the bone. The experiment revealed the nature of the mechanical stability of the embedding in relation to the increasing contact surface area. CONCLUSIONS:We observed a non-linear nature of dependences of bone density as the main parameter describing the properties of bone relative to the extent of loosening expressed in the form of the slip surface of the mandrel relative to the bone. The mechanical stability of the embedding is crucial in the initial phase of the implant healing because it eliminates the loosening of the mandrel embedding. It provides a guarantee that the specific geometry of the treated motion apparatus part will be preserved and lowers the risk of inflammatory conditions during the treatment process.
Keywords: Hip arthroplasty, bone-implant mounting, static load in the hip joint, density of hip bone, contact bone-implant, model bone-implant
DOI: 10.3233/BME-191043
Journal: Bio-Medical Materials and Engineering, vol. 30, no. 2, pp. 183-190, 2019
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]