Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Xu, Shenzhi; | Tomita, Naohide; | Ohata, Rie; | Yan, Qichang | Ikada, Yoshito
Affiliations: Institute for Frontier Medical Sciences, Kyoto University, Kyoto, Japan | Department of Sciences, Pip Tokyo Co., Ltd., Tokyo, Japan | Faculty of Medical Engineering, Suzuka University of Medical Science, Mie, Japan
Note: [] Corresponding author: Naohide Tomita, Institute for Frontier Medical Sciences, Kyoto University, 53 Kawahara‐cho, Shogoin, Sakyo‐ku, Kyoto 606‐8507, Japan. Tel./Fax:+81 75 751 4109; E‐mail: [email protected]‐u.ac.jp.
Abstract: Effects of a static magnetic field were studied on bone formation using an ischemic rat femur model. Metal rods were prepared from magnetized and unmagnetized samariun cobalt to have tapered structure, both with the same geometrical dimension, and were implanted transcortically into the middle diaphysis of 88 rat femurs. Both sides of the rat femoral artery were ligated to create an ischemic bone model, followed by implantation of the tapered rod to the femur. The bone mineral density (BMD) and weight of the femurs were measured at 1st and 3rd week after implantation. The result at the 3rd week post‐implantation revealed that the BMD and weight of the ischemic bone model rats were significantly reduced, compared with that of non‐operated femur. It was also found that the magnetized group had significantly higher bone weights than the unmagnetized (p<0.05). The BMD of the rats implanted with the magnetized rods were similar to those of the non‐operated (p>0.05). This enhancement of the femural bone formation of the ischemic rat model by the static magnetic field seems to be due to the improved blood circulation of the femur.
Keywords: Static magnetic field, bone mineral density, ischemic model, rat osteoporotic femur
Journal: Bio-Medical Materials and Engineering, vol. 11, no. 3, pp. 257-263, 2001
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]