Affiliations: [a] School of Mechanical Engineering, Shanghai Jiao Tong University, Shanghai, China | [b] School of Mechanical Engineering, Ningxia University, Yinchuan, Ningxia, China | [c] First People’s Hospital Affiliated to Shanghai Jiao Tong University, Shanghai, China
Correspondence: [*] Corresponding author: Dongmei Wang, School of Mechanical Engineering, Shanghai Jiao Tong University, Room 813, Mechanical Building A, 800 Dongchuan Road, Minhang District, Shanghai, 200240, China. Tel.: +86 21 32406798; E-mail: [email protected]
Abstract: BACKGROUND:The surrogate design and clinical diagnostic suggest that the pelvic dynamic response should be the basis of bone fracture mechanism study under side impact. Pelvic response indicators are the impact force, compression (C), viscous criterion (VC), bone stress, and bone strain. However, no evaluation of these indicators has been conducted. OBJECTIVE:To evaluate pelvic response indicators under side impact. METHODS:A sitting pelvic finite element (FE) complex model comprising bone, artery, ligaments, and soft tissue was constructed. The dynamic response of the model under side impact with initial velocity of 3 m/s was investigated and material sensitivity analysis was complemented by changing bone elastic modulus. RESULTS:The pelvic FE model could predict response under side impact. Specifically, the indicators such as artery pressure and strain, together with the ligaments axial force and strain were provided. The sensitivity analysis showed the impact force, bone stress, and axial force were sensitive to the elastic modulus, whereas, C, VC, bone strain, and artery pressure were not. CONCLUSIONS:The sitting FE model in this study can predict pelvic dynamic response, and C, VC, bone strain and artery pressure are proposed for pelvic tolerance instead of impact force under side impact.
Keywords: Pelvic complex, side impact, dynamic response, material sensitivity analysis, finite element method
DOI: 10.3233/BME-181005
Journal: Bio-Medical Materials and Engineering, vol. 29, no. 4, pp. 499-512, 2018
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]